26. SPECIFICATIONS
Distance measurement
Measuring method Coaxial phase-contrast measuring system
Signal source Red laser diode 690nm
Class 3R
(IEC60825-1 Ed. 2.0: 2007/FDA CDRH 21CFR Part1040.10 and
1040.11 (Complies with FDA performance standards for laser
products except for deviations pursuant to Laser Notice No.50, dated
July 26, 2001.))
(When the prism or reflective sheet is selected in Config mode as
target, the output is equivalent to Class 1)
Measuring range (Using the following reflective prism/reflective sheet target during
normal atmospheric conditions
*1
/
*2
is good atmospheric conditions/
*3
is conditions for the low/high temperature models)
Reflective sheet RS90N-K
*4
:
1.3 to 500m (1,640ft)
1.3 to 300m (980ft)
*3
Reflective sheet RS50N-K
*4
:
1.3 to 300m (980ft)
1.3 to 180m (590ft)
*3
Reflective sheet RS10N-K
*4
:
1.3 to 100m (320ft)
1.3 to 60m (190ft)
*3
Prism-2 X 1: 1.3 to 4,000m (13,120ft)
*7
1.3 to 5,000m (16,400ft)
*2 *7
Prism-2 X 3: 1.3 to 5,000 m (16,400ft)
*7
1.3 to 6,000m (19,680ft)
*2 *7
Prism-5: 1.3 to 500m (1,640ft)
*7
Reflectorless (White)
*5
: 0.3 to 500m (1,640ft)
0.3 to 200m (650ft)
*8
Reflectorless (Gray)
*6
: 0.3 to 220m (720ft)
0.3 to 100m (320ft)
*8
Minimum display
Fine/
Rapid
measurement
: 0.001 m (0.005ft/ 1/8 inch)
Tracking measurement: 0.01 m (0.05ft/ 1/2 inch)
Maximum slope distance display
Prism/reflective sheet: 7680m (25,196.9ft)
Reflectorless: 768m (2519.7ft)
Distance unit m/ft/inch (selectable)
Accuracy (Under normal atmospheric conditions
*1
)(ISO 17123-4 : 2001)
(Using prism)
Fine measurement: ±(2 + 2 ppm X D) mm
Rapid measurement: ±(5 + 2 ppm X D) mm
(Using reflective sheet target)
*4
Fine measurement: ±(3 + 2 ppm X D) mm
Rapid measurement: ±(5 + 2 ppm X D) mm
(Reflectorless (White))
*5
Fine measurement:
±(3 + 2ppm X D) mm (0.3 to 200m)
±(5 + 10ppm X D) mm (over 200 to 350m)
±(10 + 10ppm X D) mm (over 350 to 500m)
Rapid measurement: