Instruction manual

16. SETTING-OUT MEASUREMENT
84
5. Position the target on the line of sight and press
[MEAS] to begin distance measurement.
The distance and direction to move the target until
the setting out point is located is displayed on the
OS. The sighting point measurement results
(currently installed position of the target) are
displayed.
Switch between the tabs to display different sets
of information.
The Graph 1 tab shows the current position of
the mirror and the direction to the setting out
point from this position.
The Graph 2 tab shows the position of the setting
out point (square) and the current location of the
mirror (circle).
Move the target to find the correct distance (0 is
displayed) to the setting out point.
CMovement indicators: "16.2 Distance Setting-
out Measurement" step 6
Height difference direction
Position of poleman