Specifications

INGRESS CONFIGURATION
Sets the measurement and limit parameters for the reverse ingress scan
feature. In the Configure screen (page 1-23), highlight Ingress and press
Enter key to access the ingress options.
Start Frequency
Enter the Frequency where you want to start the Ingress
measurement. This will be the frequency at the left-hand edge of the
graph on the Ingress screen.
Stop Frequency
Enter the Frequency where you want to stop the Ingress
measurement. This will be the frequency at the right-hand edge of
the graph on the ingress screen.
Resolution
This setting determines how much detail you will see in the Ingress
graph. The higher the resolution, the longer it will take to measure
and display the results. There are four resolution settings; LOW,
MEDIUM, HIGH, and ULTRA. You can optimize the response time
depending upon how much detail you want to see.
Dwell
This is the amount of time that your CLI-1750 will spend measuring
each frequency in the Ingress graph. Increasing this value will result
in more accurate measurements while reducing it will improve the
1-34