Specifications

The first screen that will appear is a tabular list that includes the
video and audio carrier levels along with the delta V/A for each
channel. Press the Up/Down Arrows to scroll through the list.
Indicators appear within the list to flag out-of-limit conditions.
The following table relates each indicator with its meaning:
* adjacent channel limit violation (does not apply to
digital channels)
over limit violation
under limit violation
> over range measurement error
< under range measurement error
E unlocked measurement error
To view the data for the channel highlighted in the list press soft
key Sequence or the Enter key. Use the PASS/FAIL indicator to
quickly determine whether the channel has passed the limits check.
If the channel failed, you can identify the reason(s) for the failure by
looking at the symbols that appear in this indicator.
Press Sequence soft key or the Enter key again to scroll to the limit
check summary. To quickly determine the status of the overall limit
check, look at the PASS/FAIL indicator located in the upper portion
of the screen. This indicates FAIL if any channel is not within the
required limits. For each limit, the worst case value is displayed
along with a pass/fail status.
Press Cycle Through Test Points soft key to sequence through
the available test points. The test point that you have selected is
2-32