Table 9.
Parameter Min Typ Max Unit Test Conditions/Comments
POWER SUPPLY 3.0 3.3 3.6 V
LVPECL POWER DISSIPATION 1235 1490 mW
Typical part configuration, both PLLs enabled for integer-N operation,
f
OUT0
= 156.25 MHz, f
OUT1
= 125 MHz, f
OUT2
= 100 MHz, f
OUT3
= 33.33 MHz,
Na = 100, V0 = 4, D0 = 4, V1 = 4, D1 = 5, Nb = 96, V2 = 4, D2 = 6, V3 = 4,
D3 = 18, 25 MHz crystal used, load is 200 Ω to GND at output pins, then
ac-coupled to 50 Ω terminated measurement equipment
1270 1530 mW
Worst-case part configuration, PLL2 in fractional-N mode, with SSCG
enabled, f
OUT0
= 379.16 MHz, f
OUT1
= 379.16 MHz, f
OUT2
= 359.33 MHz,
f
OUT3
= 359.33 MHz, Na = 91, V0 = 3, D0 = 2, V1 = 3, D1 = 2, Nb = 86,
V2 = 3, D2 = 2, V3 = 3, D3 = 2, FRAC = 300, MOD = 1250, CkDiv = 5,
NumSteps = 77, FracStep = −7, −0.5% downspread at 32 kHz,
25 MHz crystal used, load is 200 Ω to GND at output pins, then
ac-coupled to 50 Ω terminated measurement equipment
LVDS POWER DISSIPATION 1020 1200 mW
Typical part configuration, both PLLs enabled for integer-N operation,
f
OUT0
= 156.25 MHz, f
OUT1
= 125 MHz, f
OUT2
= 100 MHz, f
OUT3
= 33.33 MHz,
Na = 100, V0 = 4, D0 = 4, V1 = 4, D1 = 5, Nb = 96, V2 = 4, D2 = 6, V3 = 4,
D3 = 18, 25 MHz crystal used, load ac-coupled to measurement
equipment that provides 100 Ω differential input termination
1085 1290 mW
Worst-case part configuration, PLL2 in fractional-N mode, with SSCG
enabled, f
OUT0
= 379.16 MHz, f
OUT1
= 379.16 MHz, f
OUT2
= 359.33 MHz,
f
OUT3
= 359.33 MHz, Na = 91, V0 = 3, D0 = 2, V1 = 3, D1 = 2, Nb = 86,
V2 = 3, D2 = 2, V3 = 3, D3 = 2, FRAC = 300, MOD = 1250, CkDiv = 5,
NumSteps = 77, FracStep = −7, −0.5% downspread at 32 kHz,
25 MHz crystal used, load ac-coupled to measurement equipment
that provides 100 Ω differential input termination
CMOS POWER DISSIPATION 1065 1380 mW
Typical part configuration, both PLLs enabled for integer-N operation,
f
OUT0
= 156.25 MHz, f
OUT1
= 125 MHz, f
OUT2
= 100 MHz, f
OUT3
= 33.33 MHz,
Na = 100, V0 = 4, D0 = 4, V1 = 4, D1 = 5, Nb = 96, V2 = 4, D2 = 6, V3 = 4,
D3 = 18, 25 MHz crystal used, eight single-ended outputs active,
C
LOAD
= 5 pF
1190 1510 mW
Worst-case part configuration, PLL2 in fractional-N mode, with SSCG
enabled, f
OUT0
= 189.58 MHz, f
OUT1
= 189.58 MHz, f
OUT2
= 179.66 MHz,
f
OUT3
= 179.66 MHz, Na = 91, V0 = 3, D0 = 4, V1 = 3, D1 = 4, Nb = 86,
V2 = 3, D2 = 4, V3 = 3, D3 = 4, FRAC = 300, MOD = 1250, CkDiv = 5,
NumSteps = 77, FracStep = −7, −0.5% downspread at 32 kHz,
25 MHz crystal used, eight single-ended outputs active, C
LOAD
= 5 pF
POWER CHANGES
Reduction in power due to turning off a channel of one VCO divider,
one output divider, and one output buffer; data for Channel 1, with
typical part configuration, both PLLs enabled for integer-N operation,
f
OUT0
= 156.25 MHz, f
OUT1
= 125 MHz, f
OUT2
= 100 MHz, f
OUT3
= 33.33 MHz,
Na = 100, V0 = 4, D0 = 4, V1 = 4, D1 = 5, Nb = 96, V2 = 4, D2 = 6, V3 = 4,
D3 = 18, 25 MHz crystal used
Power-Down 1 LVPECL Channel 160 205 mW
Load 200 Ω to GND at output pins, and ac-coupled to 50 Ω terminated
measurement equipment
Power-Down 1 LVDS Channel 105 155 mW
Load ac-coupled to measurement equipment that provides 100 Ω
differential input termination
Power-Down 1 CMOS Channel 130 170 mW Eight single-ended outputs active, C
LOAD