Use and Care Manual

Vent system must terminate to the outside
(roof or side wall).
DO NOT terminate the vent system in an at-
tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall
caps.
Use metal/aluminum vent only. Rigid metal/
aluminum vent is recommended.
DO NOT use plastic vent.
Always keep the duct clean to ensure proper
airflow.
Calculate the following figures before instal-
lation:
Maximum ceiling clearance
110” at 30” hood mounting
height above countertop/
stove (may vary with differ-
ent model).
Chimney-
mounting
Bracket
Upper
Chimney
Lower
Chimney
Range hood
1. Distance from the floor to the ceiling.
2. Distance between the oor to the coun-
tertop/stove
3. Distance between the cooking surface
to the range hood (recommend 24to
30”) minimum of 30” is required for
gas stove top
4. Height of hood and duct cover.
For the most efficient & quiet operation:
A distance of 24 to 30” is recommended
between stove top and the bottom of range
hood. 30” minimum is required for gas stove
tops.
It is recommended that the range hood be
vented vertically through the roof through 6”
(15.3 cm) or bigger round metal/aluminum
vent work.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24” (61
cm) of straight vent between the elbows if
more than one elbow is used.
DO NOT install two elbows together.
The length of vent system and number of
elbows should be kept to a minimum to pro-
vide efficient performance.
The vent system must have a damper. If
roof or wall cap has a damper, DO NOT
use damper (if supplied) on top of the range
hood.
Use silver tape or duct tape to seal all joints
in the vent system.
Use caulking to seal exterior wall or roof
opening around the cap.
Max: 110”
Min: 24
Max: 30”
36” base
Countertop/Stove
5
Venting Requirements: