REPLACEMENT INSTALLATION:
ep 5: Venting
Step 1: Measuring
Measure the distance between the cooking surface and the bottom of the range hood. A distance of
24” to 30”.
Step 2: Preparing The Hood
Remove the unit from packaging. Position the unit on a flat non-abrasive surface.
Remove the 2 filters to allow access to the inside of the unit. (See Fig #1)
Step 3: Attaching Vent/Damper
Depending on the exterior venting option chosen (See page 7), pop out the steel panel on either the top or
rear of the range hood (See Fig #2)
Using the supplied screws, attach the rectangular vent/damper to the top or rear of the range hood. (See Fig #3)
g # 4
Installations (refer to Page 4 for parts):
NOTE: Use threaded drywall anchors only when
mounting the hood on sheet rock. Mounting the hood
on wall studs or lumbars is highly recommended.
Fig #3
12
Fig # 2
Step 4: Installing the Hood
Using measurements provided on Page 16, measure and drill
4 holes into bottom of cabinet. (See Fig #4)
Depending on exterior venting chosen (See page 7), use
measurements provided on Page 16 and cut vent hold in cabinet.
Align range hood to the holes in the bottom of the cabinet and
screw in using the supplied screws. (See Fig #4
)
Fig #4
Fig #
1