User`s manual

<6. Wiring>
6-4
IM 01C25B01-01E
■ Fourwireconnection
Fasten the negative side wiring of both power
supply and signal line to the SUPPLY - terminal.
Hazardous Location Nonhazardous Location
Transmitter terminal box
Distributor
(Power supply unit)
Receiver
instrument
F0618.ai
Figure6.12 ConnectionbetweenTransmitter,
DistributerandReceiver
6.4.2 Wiring Installation
(1) General-use Type and Intrinsically Safe
Type
With the cable wiring, use a metallic conduit or
waterproof glands.
• Applyanon-hardeningsealanttotheterminal
box connection port and to the threads on the
exiblemetalconduitforwaterproong.
F0608.ai
Flexible metal conduit
Wiring metal
conduit
Tee
Drain plug
Apply a non-hardening
sealant to the threads for
waterproofing.
Figure6.13 TypicalWiringUsingFlexibleMetal
Conduit
(2) Flameproof Type
Wirecablesthroughaameproofpackingadapter,
oruseaameproofmetalconduit.
■ Wiringcablethroughameproofpacking
adapter.
• Applyanon-hardeningsealanttotheterminal
box connection port and to the threads on the
ameproofpackingadapterforwaterproong.
Flameproof packing
adapter
Flexible metal conduit
Wiring metal
conduit
Tee
Drain plug
Apply a non-hardening
sealant to the threads for
waterproofing.
F0609.ai
Figure6.14 TypicalCableWiringUsingFlameproof
PackingAdapter
■ Flameproof metal conduit wiring
• Asealttingmustbeinstalledneartheterminal
box connection port for a sealed construction.
• Applyanon-hardeningsealanttothethreadsof
theterminalboxconnectionport,exiblemetal
conduitandsealttingforwaterproong.
F0610.ai
Non-hazardous area
Hazardous area
Flameproof
heavy-gauge
steel conduit
Tee
Drain plug
Seal fitting
Gas sealing device
Flameproof flexible
metal conduit
Apply a non-hardening
sealant to the threads of
these fittings for
waterproofing
After wiring, impregnate the fitting
with a compound to seal tubing.
Figure 6.15 Typical Wiring Using Flameproof Metal
Conduit