User`s manual

<7. Operation>
7-6
IM 01C25B01-01E
7.6.1 Local Parameter Setting (LPS)
Overview
Parametercongurationbytheexternaladjustment
screw and push button (integral indicator code E)
offerseasyandquicksetupforparametersofTag
number, Unit, LRV, URV, Damping,Output mode
(linear/squareroot),Displayout1,andRe-range
by applying actual pressure (LRV/URV). There is
no effect on measurement signal (analog output
or communication signal) when Local Parameter
Setting is carried out.
External adjustment
screw cover
F0708.ai
Figure 7.7 External Adjustment Screw
F0709.ai
Integral indicator
Push-button
Figure7.8 Range–SettingSwitch(pushbutton)
F0710.ai
screw
push
push
push
push
push
push
Save/Cancel the value
Save/Cancel the value
Save/Cancel the value
Save/Cancel the value
Save/Cancel the value
Save/Cancel the value
Save/Cancel the value
Save/Cancel the value
Save/Cancel the value
6. Output Mode
2. Press Unit
1. Tag Number
*
*
*
*
*
*
*
3. Press LRV
4. Press URV
7. Display Out1
8. LRV-Apply Press
9. URV-Apply Press
5. Damping Time
Select Output mode
Select Press unit
Edit Tag number
Edit Press LRV
Edit Press URV
Edit Display Out1
Set LRV
Set URV
Edit Damping time
Process
Measurement
Display
Zero adjustment
8, 9 : Re-range by applying actual pressure
Displayed when output signal code is Q.
Process
Measurement
Display
10. Device Information
Activate LPS mode
*:Notethattheabove1to7parametercongurationsareavailablewiththesoftwarerevision(SOFTREV)2.03orlater.
Softwarerevisioncanbecheckedviaaeldcommunicator(HART/BRAIN)orDTM.PleaserefertoIM01C25T01forHARTparameter
“Software rev” and IM 01C25T03 for BRAIN “SOFT REV”.
Figure 7.9