User`s manual

<9.GeneralSpecications>
9-9
IM 01C25B01-01E
Model EJX310A
Model SufxCodes Description
EJX310A . . . . . . . . . . . . . . . . . . . . . . Absolute pressure transmitter
Output
signal
-D . . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . . .
-J . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . .
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART protocol)
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
Digital communication (F
OUNDATION Fieldbus protocol,
refer to IM 01C25T02-01E)
Digital communication
(PROFIBUS PA protocol, refer to IM 01C25T04-01EN)
Measurement
span (capsule)
L . . . . . . . . . . . . . . . . . . .
M . . . . . . . . . . . . . . . . . .
A. . . . . . . . . . . . . . . . . . .
B. . . . . . . . . . . . . . . . . . .
0.5 to 10 kPa abs (0.15 to 2.95 inHg abs)
1.3 to 130 kPa abs (0.39 to 38 inHg abs)
0.0175 to 3.5 MPa abs (2.5 to 500 psia)
0.08 to 16 MPa abs (12 to 2300 psia)
Wetted parts
material *
1
S . . . . . . . . . . . . . . . . . . Refer to Table. 1 Wetted Parts Materials on Page 9-18.
Process
connections
0 . . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . .
5 . . . . . . . . . . . . . . . .
withoutprocessconnector(Rc1/4femaleonthecoveranges)
with Rc1/4 female process connector
with Rc1/2 female process connector
with 1/4 NPT female process connector
with 1/2 NPT female process connector
withoutprocessconnector(1/4NPTfemaleonthecoveranges)
Bolts and nuts
material
J . . . . . . . . . . . . . .
G. . . . . . . . . . . . . .
C. . . . . . . . . . . . . .
ASTM-B7 carbon steel
316L SST stainless steel
ASTM grade 660 stainless steel
Installation
-2 . . . . . . . . . . .
-3 . . . . . . . . . . .
-6 . . . . . . . . . . .
-7 . . . . . . . . . . .
-8 . . . . . . . . . . .
-9 . . . . . . . . . . .
-B . . . . . . . . . . .
-U . . . . . . . . . . .
Vertical piping, right side high pressure, and process connection upside
Vertical piping, right side high pressure, and process connection downside
Vertical piping, left side high pressure, and process connection upside
Vertical piping, left side high pressure, and process connection downside
Horizontal piping and right side high pressure
Horizontal piping and left side high pressure
Bottom process connection, left side high pressure
Universalange
Amplierhousing 1 . . . . . . . . . .
2 . . . . . . . . . .
3 . . . . . . . . . .
Cast aluminum alloy
ASTM CF-8M stainless steel
Cast aluminum alloy with corrosion resistance properties
Electrical connection
0 . . . . . . . . .
2 . . . . . . . . .
4 . . . . . . . . .
5 . . . . . . . . .
7 . . . . . . . . .
9 . . . . . . . . .
A. . . . . . . . .
C. . . . . . . . .
D. . . . . . . . .
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs
M20 female, two electrical connections without blind plugs
G1/2 female, two electrical connections and a blind plug
1/2 NPT female, two electrical connections and a blind plug
M20 female, two electrical connections and a blind plug
G1/2 female, two electrical connections and a 316 SST blind plug
1/2 NPT female, two electrical connections and a 316 SST blind plug
M20 female, two electrical connections and a 316 SST blind plug
Integral indicator
D. . . . . . .
E . . . . . . .
N. . . . . . .
Digital indicator
Digital indicator with the range setting switch (push button)
None
Mountingbracket B. . . . .
D. . . . .
G. . . . .
J . . . . .
K. . . . .
M . . . .
N. . . . .
304SST2-inchpipemounting,attype(forhorizontalpiping)
304 SST 2-inch pipe mounting, L type (for vertical piping)
304 SST 2-inch pipe mounting (for bottom process connection type)
316SST2-inchpipemounting,attype(forhorizontalpiping)
316 SST 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting (for bottom process connection type)
None
Optional codes
/
Optionalspecication
The►”marksindicatethemosttypicalselectionforeachspecication.
*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandinuenceofprocessuids.Specifyinginappropriate
materials has the potential to cause serious damage to human body and plant facilities resulted from an unexpected leak of the
corrosiveprocessuids.