User`s manual

<9.GeneralSpecications>
9-14
IM 01C25B01-01E
Model EJA130E
Model SufxCodes Description
EJA130E . . . . . . . . . . . . . . . . . . . . . . . . . . . . Differential pressure transmitter
Output
signal
-D . . . . . . . . . . . . . . . . . . . . . . . . . .
-J . . . . . . . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . . . . . . . .
-Q . . . . . . . . . . . . . . . . . . . . . . . . . .
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication
(HART 5/HART 7 protocol)
Digital communication (F
OUNDATION Fieldbus protocol,
refer to IM 01C25T02-01E)
Digital communication (PROFIBUS PA protocol, refer to
IM 01C25T04-01EN)
Low Power, 1 to 5 V DC with digital communication (HART 7
protocol)
Measurement
span (capsule)
M . . . . . . . . . . . . . . . . . . . . . . . .
H. . . . . . . . . . . . . . . . . . . . . . . . .
1 to 100 kPa (4 to 400 inH
2
O)
5 to 500 kPa (20 to 2000 inH
2
O)
Wetted parts
material
*1
S . . . . . . . . . . . . . . . . . . . . . . Refer to Table.1 Wetted Parts Material on Page 9-18
Process connections
3 . . . . . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . . . . . .
5 . . . . . . . . . . . . . . . . . . . .
with 1/4 NPT female process connector
*2
with 1/2 NPT female process connector
*2
withoutprocessconnector(1/4NPTfemaleonthecoveranges)
Bolts and nuts materia J . . . . . . . . . . . . . . . . .
G. . . . . . . . . . . . . . . . .
C. . . . . . . . . . . . . . . . .
B7 carbon steel
316L SST
660 SST
Installation
-2 . . . . . . . . . . . . . .
-3 . . . . . . . . . . . . . .
-6 . . . . . . . . . . . . . .
-7 . . . . . . . . . . . . . .
-8 . . . . . . . . . . . . . .
-9 . . . . . . . . . . . . . .
-U . . . . . . . . . . . . . .
Vertical piping, right side high pressure, and process connection
upside
Vertical piping, right side high pressure, and process connection
downside
Vertical piping, left side high pressure, and process connection
upside
Vertical piping, left side high pressure, and process connection
downside
Horizontal piping and right side high pressure
Horizontal piping and left side high pressure
Universalange
Amplierhousing 1 . . . . . . . . . . . . .
3 . . . . . . . . . . . . .
2 . . . . . . . . . . . . .
Cast aluminum alloy
Cast aluminum alloy with corrosion resistance properties
ASTM CF-8M stainless steel
Electrical connection
0 . . . . . . . . . .
2 . . . . . . . . . .
4 . . . . . . . . . .
5 . . . . . . . . . .
7 . . . . . . . . . .
9 . . . . . . . . . .
A. . . . . . . . . .
C. . . . . . . . . .
D. . . . . . . . . .
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs
M20 female, two electrical connections without blind plugs
G1/2 female, two electrical connections and a blind plug
1/2 NPT female, two electrical connections and a blind plug
M20 female, two electrical connections and a blind plug
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug
Integral indicator
D. . . . . . . .
E . . . . . . . .
N. . . . . . . .
Digital indicator
Digital indicator with the range setting switch (push button)
None
Mountingbracket B. . . . .
D. . . . .
J . . . . .
K. . . . .
N. . . . .
304SST2-inchpipemounting,attype(forhorizontalpiping)
304 SST 2-inch pipe mounting, L type (for vertical piping)
316SST2-inchpipemounting,attype(forhorizontalpiping)
316 SST 2-inch pipe mounting, L type (for vertical piping)
None
Optional Codes
/
Optionalspecication
The►”marksindicatethemosttypicalselectionforeachspecication.
*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandinuenceofprocessuids.Specifyinginappropriate
materials has the potential to cause serious damage to human body and plant facilities resulted from an unexpected leak of the
corrosiveprocessuids.
*2: Lower limit of ambient and process temperature is -15°C.