User`s manual

<9.GeneralSpecications>
9-20
IM 01C25B01-01E
Item Description Code
Oil-prohibited use *
4
Degrease cleansing treatment. K1
Degreasecleansingtreatmentandwithuorinatedoillledcapsule.
Operating temperature20 to 80°C( –4 to 176°F)
K2
Oil-prohibited use with
dehydrating treatment *
4
Degrease cleansing treatment and dehydrating treatment.
K5
Degreasecleansingtreatmentanddehydratingtreatmentwithuorinatedoillled
capsule. Operating temperature –20 to 80°C(4 to 176°F)
K6
Capsulelluid Fluorinatedoillledincapsule
Operating temperature20 to 80°C( –4 to 176°F)
K3
Calibration units *
5
P calibration (psi unit)
(See Table for Span and
Range Limits.)
D1
bar calibration (bar unit) D3
M calibration (kgf/cm
2
unit) D4
Long vent *
6
Total length: 119 mm (standard: 34 mm); Total length when combining with
Optional code K1, K2, K5, and K6: 130 mm. Material: 316SST.
U1
Gold-plated capsule gasket
*
13
Gold-plated 316L SST capsule gasket. No PTFE is used for wetted parts.
GS
Gold-plated diaphragm *
14
Surface of isolating diaphragm is gold plated, effective for hydrogen permeation. A1
130 Pa abs calibration *
12
Minimum input puressure at calibration testing: 130 Pa abs (1 mmHg abs) S1
Output limits and failure
operation *
7
Failure alarm down-scale: Output status at CPU failure and hardware error is
–5%, 3.2 mA DC or less. *
30
C1
NAMUR NE43 Compliant
Output signal limits:
3.8 mA to 20.5 mA *
31
Failure alarm down-scale: Output status at CPU
failure and hardware error is5%, 3.2 mA DC or less.
C2
Failure alarm up-scale: Output status at CPU
failure and hardware error is 110%, 21.6 mA or more.
C3
Body option *
8
Without drain and vent plugs N1
N1 and Process connection, based on IEC61518 with female thread on both sides
ofcoverange,withblindkidneyangesonback.
N2
N2andMaterialcerticateforcoverange,diaphragm,capsulebody,andblind
kidneyange
N3
Stainless steel tag plate 304SST tag plate wired onto transmitter N4
Datacongurationat
factory *
9
DatacongurationforHART
communication type
Software damping, Descriptor, Message
CA
DatacongurationforBRAIN
communication type
Software damping
CB
European Pressure
Directive *
10
PED 97/23/EC
Category:III,Module:H,TypeofEquipment;PressureAccessory-Vessel,Typeof
Fluid;Liquidandgas,GroupofFluid:1and2
Lower limit of Process and Ambient temperature for EJX110A : –29°C
PE3
Advanced diagnostics *
27
Multi-sensing process monitoring
•Impulselineblockagedetection*
28
•Heattracemonitoring
DG6
Materialcerticate*
15
Coverange*
16
M01
Coverange,Processconnector*
17
M11
Pressure test/
Leaktestcerticate
Test Pressure: 16 MPa (2300 psi) *
18
Nitrogen(N
2
) Gas *
25
Retention time: one minute
T12
Test Pressure: 25 MPa (3600 psi) *
19
T13
Test Pressure: 3.5 MPa (500 psi)*
20
T01
Test Pressure: 500 kPa (2000 inH
2
O) *
21
T11
Test Pressure: 50 kPa (200 inH
2
O) *
22
T04
Test Pressure: 32 MPa (4500 psi) *
23
Nitrogen(N
2
) Gas or water *
26
Retention time: one minute
T09
Test Pressure: 50 MPa (7200 psi) *
24
T08
High accuracy type High accuracy HAC
High pressure-proof
structure
Maximum working pressure for differential pressure measurement: 25MPa*
29
HG
Contact Yokogawa representative for the codes indicated as ‘-’.
*1: Applicable for Electrical connection code 2, 4, 7, and 9.
*2: Applicable for Electrical connection code 2 and 7.
*3: Not applicable for option code /AL.
*4: Applicable for Wetted parts material code S, H, M, and T.
*5: TheunitofMWP(Max.workingpressure)onthenameplateofthehousingisthesameunitasspeciedbyOptioncodeD1,D3,
and D4.