User's Manual

U
SER
´
S MANUAL FOR BAND SELECTIVE REPEATERS
MR
X
03P
User'sManual.doc Id.-No.:154999 Page 33 22-Jan-01
5.4. REMOTE SETTINGS
After the boot process, the software login is possible. All parameters of the software
can be changed by the provider to optimize the repeater according to the network
system. There are two possibilities how to login to the software:
locally via a VT100 terminal or a PC with VT100 terminal emulation
remotely via a modem e.g. with the Operations and Maintenance Center (OMC)
5.4.1. Local Login
The login via VT100 terminal or a PC with VT100 emulation can only be performed at
the repeater. Open the repeater carefully and ensure that DIP-switch 2 of mode-
switch [1] is in position OFF. Only when DIP-switch 2 is OFF, a local access to the
software on the control module is possible (see chapter 5.3 DIP-Switches).
Connect the terminal or PC to the RS232 interface on the control module by means
of a standard RS232 interface cable (see picture below).
Terminal or PC Control Module SM2009
9 contact SUB-D-connector 9 contact SUB-D-connector
male male
Pin Pin
1
2
3
4
5
6
7
8
9
8
9
7
6
1
3
4
5
2
Check the communication mode at the terminal. If necessary, set the following
parameters:
Bit rate / bit per second: 9600 baud Number of data bit: 8 bit
Parity bit: No parity Stopbit: 1 stopbit