Installation guide

INSTALLATION SECTION 3
External wiring to the water heater(s) must be installed in accordance with current I.E.E.
Regulations for the wiring of buildings and to any Local Regulations that may apply.
The EC
O
flo range is designed to operate from a 230V, single phase supply.
The fuse rating is 5 amps.
The method of connection to the mains electricity supply should facilitate complete
Electrical isolation of the appliance, preferably by use of a fused double pole switch or
fused spur box serving only the heater. The disconnection of the supply shall have a
contact separation of 3mm on all poles. The double pole switch for the water heater
electrical supply must be located where it can be easily reached under all circumstances.
The point of connection to the mains electricity supply should be readily accessible through
a cable entry gland at the rear of the appliance on the combustion assembly surround.
Connect the electrical supply to the main control panel terminal block via the cable gland.
Mains input cable should be 0.75mm
2
3 core, and should be connected to the mains
supply as detailed above.
Mains Voltage: 230V - IP 20
Frequency: 50Hz
Fuse: 5 Amps
ELECTRICAL
SUPPLY
17