Installation guide

INSTALLATIONSECTION 3
Installation Procedure
Determine location of flue exit.
1. The Horizontal or Vertical flue kit that has been delivered includes the components as
listed below and on page 21. The concentric flue pipe system includes both the flue
exhaust (inside pipe) and combustion air (outside pipe). The flue pipe may be cut on the
unflared end (end without gasket) as required for the installation.
2. Determine if additional flue components are required for the installation. Refer to the
flue component information on pages 21 and 55 for available optional flue components.
3. Ensure that the flue terminal location complies with requirements described within this
manual and the Local Codes of Practice.
4. Measure the vertical and horizontal distance from the water heater flue connection to
determine the number of components required.
HORIZONTAL FLUE KIT/FITTINGS PACK - 230 LITRE MODELS AWH PART No: B291
SUPPLIED COMPONENTS
Part Description Part Number
Exhaust Outlet Tee c/w Condense Outlet (82500) E860
100mm to Concentric Exhaust Connector (75412) E861
Air intake Tee Piece Connector (82501) E862
Condense Syphon (87436) E863
Horizontal Flue Terminal, 100/150mm (87990) E236
90º Elbow c/w clamp, 100/150mm (87890) E205
Gas Cock - 3/4” BSP C498
Drain Valve - 3/4” BSP C381
Drain Valve Socket - 3/4” BSP C103
Installation, Operation and Maintenance Manual E864
VERTICAL FLUE KIT/FITTINGS PACK - 230 LITRE MODELS AWH PART No: B293
SUPPLIED COMPONENTS
Part Description Part Number
Exhaust Outlet Tee c/w Condense Outlet (82500) E860
100mm to Concentric Exhaust Pipe (75412) E861
Air intake Tee Piece Connector (82501) E862
Condense Syphon (87436) E863
Vertical Flue Terminal, 100/150mm (87969) E866
Gas Cock - 3/4” BSP C498
Drain Valve - 3/4” BSP C381
Drain Valve Socket - 3/4” BSP C103
Installation, Operation and Maintenance Manual E864
HORIZONTAL
AND VERTICAL
FLUE KITS
20