Installation guide

INSTALLATION SECTION 3
The EC
O
flo uses a concentric flue system, 150mm outside diameter with an inner flue
of 100mm diameter.
Flue components fit together with silicon sealing rings and the flues are retained with
sealing clamps. Each heater can be ordered with either a horizontal or vertical flue kit.
Flue assembly instructions are also included.
Prior to installing the concentric flue system and terminal the following must be
carried out:
1) Fit item E860 to stainless steel exhaust outlet connection on the appliance and ensure
that the condense connection is at the base of the tee piece.
2) Fit item E862 to PVC air intake connection on appliance and ensure that open end is at
the top of the tee piece.
3) Fit item E861 or E865 depending on the model to both previously fitted E860 and E862
and ensure that both connectors are located correctly. Secure the 100mm dia. vertical
section of item E861 or E865 to heater outer casing with brackets supplied.
4) Fit item E863 condense syphon to 32mm connection at base of condense tee (E860).
5) Install 40mm OD plastic waste system from syphon outlet to suitable drain.
A minimum downward slope of between 3mm to 6mm per 300mm
length of waste pipe must be adhered to.
EC
O
flo
230 & 380
LITRE FLUE
SYSTEMS
E861
(230 Litre)
E865
(380 Litre)
E862
E860 + E863
Condense
pipe to drain
Condense
syphon
23