Installation guide

INSTALLATIONSECTION 3
Wall Anchor
(4 Places)
Screw
(Supplied)
(4 Places)
flue Terminal
Outer Wall
Mount Plate
Intake Air Openings
(Must Face Ground)
Hole through Wall
Wall Anchor
(4 Places)
Screw
(Supplied)
(4 Places)
Flue Terminal
Inner Wall
Mount Plate
Hole through Wall
26
INSTALLING THE HORIZONTAL FLUE TERMINAL
NOTE! The horizontal flue terminal supplied may be used through outside walls up to
600mm (24in) thick.
1. Horizontal flue Terminal (Through the Wall) supplied
a) Cut an opening of at least 165mm (6.5in) diameter through the outside for the EC
O
flo
models.
b) Slide the flue terminal through the wall opening to the rib closest to the intake air
openings of the terminal even with the outside wall.
FLUE
SYSTEMS
c) Slide the outside wall plate over the flue terminal and fasten to the wall with four screws.
Depending on the wall construction, wall anchors may be required to reinforce
the screws.
d) Install inside wall plate on the inside wall and secure with four screws. Depending on wall
construction, wall anchors may be required to reinforce the screws.
Fig.4
Fig.5