OPERATING INSTRUCTIONS SECTION 5
During the winter season or any cold period, you may desire a higher temperature setting
to adjust for the colder incoming water. This adjustment, however, may cause additional
condensation to form on the colder tank surface. This does not mean the tank is leaking.
During summer months, the warmer incoming water temperatures will benefit the
performance of your water heater and reduce the amount of condensation developed.
Condensation does not mean your tank is leaking. Most of reported tank leaks on
installation are proven to be condensation. To avoid unnecessary inconvenience and
expense, make sure the tank is actually leaking before containing Andrews Water-Heaters.
If the water heater is to remain idle for 30 days or more or is subjected to freezing
temperatures while shut off, the water heater and piping should be fully drained and the
drain valve should be left fully open. Refer to the relevant section of this Installation and
Operating Instructions Manual for the procedure on draining the water heater.
This water heater is equipped with an energy cut out device to prevent overheating. Should overheating occur or the
gas supply fails to shut off, turn off the manual gas control valve to the appliance and call a qualified service company.
DANGER
BURNER
FLAME CHECK
TEMPERATURE
ADJUSTMENT
Sight Glass Location
41
Fig.16