User Manual

With the Eclipse 384 on standby mode, press and hold Preset button 1 (immediately to the
right of the Antelope button);
While holding it, click the power button of the Eclipse 384;
Leave the buttons and wait for 1 minute to allow the units to stabilize;
You will see “Calibration” displayed on the LCD Screen along with “Heating Up” and the
temperature of the Oven;
Wait for the calibration to take place;
When the Err. Number becomes stable, press Preset button 1 again to end the calibration;
You will see “DONE” displayed on the LCD screen.
12. Device Information
Device information, such as Firmware version, Hardware version and Serial Number can be
displayed on the LCD screen by following these steps:
With the device on standby mode (turned off), press Preset 1 and while holding it press the
power button;
Press any other Preset button to bring the device to operating mode.
13. In the box
Eclipse 384kHz Stereo HD Mastering A/D, D/A CCM
Owner’s Manual