User Guide
16 Page
Installaon
Installaon Manual
Ventconneconsfortwo-pipe
4" stainless
steel vent
straight pipe
Exhaust vent
collar (Female)
Intake vent collar
(Female)
4" stainless
steel vent
straight pipe
Exhaust vent
collar (Female)
4" stainless
steel vent
straight pipe
Intake vent
collar
(Female)
4"elbow
withbird
screen
1. Connecta4"stainlesssteelvent
straight pipes directly on the
exhaust vent collar of the
water heater.
2. Connecta4"elbowdirectly
on the intake vent collar of the
water heater.
1. Connect4"stainlesssteelvent
straight pipes directly on the
exhaust/intake vent collar of the
water heater.
For details of the optional items, refer to the Installation manual for each Optional item.
-Exhaust vent (Stainless steel vent)-
This is a Category IV appliance and must be vented accordingly. The vent system must be sealed airtight.
All seams and joints withoutgaskets must be sealed with high heat resistant silicone sealant or UL listed
aluminum adhesive tape having a minimum temperature rating of 160 °F. For best results, a vent system
should be as short and straight as possible.
• The Indoor model is a Category IV appliance and must be vented accordingly with any 4 inch vent
approved for use with Category III/IV or Special BH type gas vent.
• ThemanufacturerrecommendstheNovaVent(Z-Vent)line. However, the following are also UL
listed manufacturers: ProTech Systems Inc. (FasNSeal), Metal-Fab Inc., and Heat-Fab Inc. (Saf-T
Vent).
• Followtheventpipemanufacturer’sinstructionswheninstallingtheventpipe.
• The maximum length of exhaust vent piping must not exceed 100 ft. (30.5 m) (deducting 5 ft. (1.5
m) for each elbow used in the venting system). Do not use more than 5 elbows.
• When the horizontal vent run exceeds 5 ft. (1.5 m), support the vent run at 3 ft. (0.9 m) intervals
with overhead hangers.
Diameter Max.No.ofElbows Max.VerticalandHorizontal(Total)VentLength
4 in. (102 mm) 5 100 ft. (30.5 m )
*Foreachelbowadded,deduct5ft.(1.5m)frommax.ventlength.
No.ofElbows Max.VerticalorHorizontalVentLength
0 100 ft. (30.5 m)
1 95 ft. (29.0 m)
2 90 ft. (27.4 m)
3 85 ft. (25.9 m)
4 80 ft. (24.4 m)
5 75 ft. (22.9 m)
Excludes vent terminators, termination elbows, or rain caps.
Ventconneconsforsinglepipe