OPTIONAL ITEMS
# Model
140
Indoor
(T-H3M-DV)
140
Outdoor
(T-H3M-OS)
1.
Temperature Remote Controller
Included with the
water heater
2.
Pipe Cover
3.
Neutralizer Kit
4.
4-inch Exhaust Sidewall Vent Terminator (Hood)
and 4-inch Wall Thimble
5.
3-inch Concentric PVC
Termination
6.
Recess Box
The pipe cover protects the plumbing pipes to
the water heater from unexpected adjustments.
This pipe cover is fixed to the bottom of the water
heater, which hides the plumbing and improves
the visual aspects of the whole installation for the
water heater.
The temperature remote controller has three functions. It allows the output temperature from the
water heater to be adjusted within the range of 100 °F to 140 °F, and also works as a diagnostic
tool and will provide a concise error code whenever there is a problem with the water heater. The
temperature options are 100 °F, 105 °F, 110 °F, 115 °F, 120 °F, 125 °F, 130 °F, 135 °F, and 140 °F. See
the troubleshooting Section for information on possible error codes.
1.TemperatureRemoteController:
9009069005(TM-RE42)
2.PipeCover:9008953005(TH-PC04)
3.NeutralizerKit:9007607005(TH-NT01)
The neutralizer assembly neutralizes
the condensate (acidic water) that
forms in the secondary heat exchanger
of the water heater.
It connects to the condensate
drain port of the water heater by
using connectors included with the
neutralizer kit. Refer to p. 23 and 24
for the details.
Installaon
Installaon Manual