Installation and Operation Manual Back-UPS® BR1000G-BR Inventory Safety bu001a This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Do not block the air vents on this unit. Connect the battery bu055a bu057a bu059a Charge the battery for at least 16 hours before use.
PowerChute® Personal Edition Software Overview PowerChute Personal Edition Software allows you to use your computer to access additional power protection and management features of the Back-UPS. Using PowerChute, you can: • Preserve work in progress during a power outage by putting your computer into Hibernate mode. When the power returns, the computer will appear exactly as it did before the power outage.
Connect the equipment Cable In Cable out Battery Backup PowerChute Port USB & Serial Battery Backup and Surge Protected outlets When the Back-UPS is receiving input power, the Surge Protection only outlets and the Battery Backup with Surge Protection outlets will supply power to connected equipment. During a power outage or other utility problems, only the Battery Backup outlets receive power for a limited time from the Back-UPS.
Operation Power-Saving Function To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes into Sleep or Standby mode, or is switched OFF, the Controlled device(s) will be switched off as well, saving electricity.
Front Panel Buttons and Display Interface Use the three buttons on the front panel of the Back-UPS and the display interface to configure the Back-UPS.
Warnings and System Faults Audible Warnings Four Beeps Every 30 Seconds Continuous Beeping Continuous tone Back-UPS is running on battery. You should consider saving any work in progress. Low battery condition and battery run-time is very low. Promptly save any work in progress, exit all open applications, and shut down the operating system. Battery Backup outputs are overloaded. Chirps for 1 Minute every 5 hours Battery fails the automatic diagnostic test and should be replaced.
Function Button Quick-Reference Function Button Timing (seconds) UPS Status Description Power Power On 0.2 Off Press POWER to start receiving input A/C power. If A/C input power is not available, the Back-UPS will run on battery power. Power Off 2 On The Back-UPS is not receiving input A/C power, but is providing surge protection. 0.2 On Verify the status or condition of the Back-UPS. The LCD will illuminate for 60 seconds.
Troubleshooting Problem Back-UPS will not turn on. Possible Cause The Back-UPS is not connected to A/C power. The circuit breaker has been tripped. The internal battery is not connected. The A/C input voltage is out of range. The Back-UPS does not provide Ensure that essential equipment is not power during a A/C power plugged into a SURGE ONLY outlet. outage.
Specifications t Model BR1000G-BR VA 1000 VA Maximum Load 600 W Nominal Input Voltage 120 V Online Input Voltage Range 88 V to 141 V Automatic Voltage Regulation 94 V-107 V +11.2% 126 V-141 V -11.
Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Review the TROUBLESHOOTING section of the manual to eliminate common problems. 2. If the problem persists, contact APC Customer Support through the APC Web site, www.apc.com. a. Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models. b.