Owners manual

- 9 -
System Ground Terminal
The H15 provides for the connection of grounding wires from
all of your equipment to a central terminal lug. This ground
connection eliminates ground loop problems; tie all component
grounds to this screw to break any possible ground loops that
can cause an audible ‘hum’.
Circuit Breaker
The H15 also provides a “press-to-reset” circuit breaker. When
this breaker is “tripped” due to an electrical surge or overload,
the device pops out and shuts down output power to the outlets.
To reset the circuit breaker, push it straight inward.
Caution: When resetting the Circuit Breaker, push the button in
quickly, and release the button. Do not hold the button inward.
Failure to comply may result in equipment damage.
Input Power Connector
Connect one end of the supplied AC power cord to the H15
Input Power Connector, connect the other end to the AC utility
power source (12 Amp, 120 Vac, 50-60 Hz).
DC Trigger jacks
When connected to a component acting as a DC trigger, that
component controls turn on/off of the ‘delayed’ outlet banks.
The H15 also allows that DC signal to pass through to another
connected component.
CAUTION: When connecting to the DC Trigger jacks, connect
the source of the DC trigger to the IN jack. The OUT jack
should be used only as a pass-through. The DC Trigger signal
can be short circuited if the input and output cables are
reversed. The maximum input voltage for the DC Trigger is
30VDC. Do not apply an AC voltage to the DC trigger jacks.
Failure to comply with this statement may result in equipment
damage.
3
4
5
6