Owners manual

- 13 -
AVR Range Function - Allows you to adjust the AVR Range of the H15.
APC recommends the following settings:
“Wide” if the line voltage in your area is not stable.
“Narrow” if the line voltage in your area is stable (generally around
120V).
Press the Setup push button until the “SET AVR RANGE ?” menu is dis-
played as shown in Figure 6. Then press the Select push button to change
the AVR Range setting. After you select the proper AVR Range setting,
press the Setup push button to accept the setting.
Figure 6. AVR Range Display
The AVR Range adjustments have the following value:
Narrow AVR Range: 102-132 Volts, Regulates to: 120 Volts + 5%.
Normal AVR Range: 97-139 Volts, Regulates to: 120 Volts + 10%.
Wide AVR Range: 92 - 145V, Regulates to: 120V + 15%.
Delay Time Function — Allows you to set the delay on/off time for the
sequence delayed outlets. By pressing the Setup push button until the
“SET DELAY TIME ?” menu is displayed (Figure 7). Then press the
Select push button to select the proper delay seconds (0-12 seconds). Press
the Setup push button to store the setting.
Figure 7. Delay Time Display
Beeper Function — Allows you to enable or disable the beeper sound.
Repeatedly press the Setup push button to advance to the “SET
BEEPER ?” menu (Figure 8). Press the Select push button to toggle the
beeper between ON and MUTE. When enabled (OK), a beeping sound is
made each time the Setup or Select push buttons are pressed. When dis-
abled (Mute), the beep is turned off. Press the Setup push button to store
the setting.
SET AVR RANGE ?
<Others Yes>
SET DELAY TIME ?
<Others Yes>