Instructions / Assembly

APEC RO-PH90 System Filter Change Instruction
Changing Stages-1, 2, 3 Pre-Filters: (should be changed at least every 12 months)
1) Turn OFF cold water supply to RO system. Turn OFF the tank ball valve. Turn ON RO faucet briefly to relieve the built-up
pressure inside the RO system. This will make opening the housings easier.
2) Open housing: Have the RO standing upright. Slip the plastic wrench onto the #1 housing. Looking down from a top
view, you should open the housing turning clockwise. If necessary, lay RO down on the floor to get a better leverage. If
the housing is too tight, use a hammer and lightly tap on the wrench handle to help turn the wrench.
3) Discard 3 used filters, wash housings with mild soap, rinse off. Put 3 new filters into their respective housings: sediment
filter in stage-1, carbon block filters in stage-2 and stage-3.
4) Close up the housings. Make sure each housing has a black O-ring in the thread groves. Use wrench to tighten each
housing.
5) Remember: Turn ON the cold water supply and OPEN the tank valve after finished changing filters!
6) Check for leaks!
Changing Stage-4 Membrane: (should be changed every 3-5 years)
1) Turn OFF cold water supply to RO system. Turn OFF the tank ball valve. Turn ON RO faucet briefly to relieve the built-up
pressure inside the RO system. This will make opening the housings easier.
2) See Fig. B. Locate the Membrane housing on the system (labeled “Membrane”). Remove the RED tubing from the
housing’s cap at point D. To remove tubing, push in and Hold Down on the collet ring square against the fitting. With
the collet held in this position the tubing can be removed. Open up the cap (turn counter-clockwise). Remove the used
membrane. Discard. Insert the new membrane using a pair of pliers. Push membrane into housing tightly. Avoid
touching the Membrane with your hands to prevent contamination!
3) Important! Make sure the “double-ring” end of the membrane goes into the housing first as shown in Fig. A. above.
The membrane cannot filter water if it’s inserted in the WRONG direction!
4) Close the housing cap. Reconnect the RED tubing to the cap. Turn on the cold water supply and open the tank valve.
Let the RO system run to re-fill the tank (takes about 2-3 hours).
5) Check for leaks!
6) Drain the first tank of water (through faucet) to flush out the new membrane! The 2
nd
tank of water is ready for use.
Fig. A
3rd
Stage
2nd
Stage
1st
Stage
STEP1 STEP2
Use
Wrench
W
W
After taking the housings off, take out the dirty filters
and put the new 3 pre-filters in. Remember, Stage-2 and
Stage-3 are same carbon filters.
1