8
Adjustment
1. DETECT Switch For shifting the magnetizing state of the
output relay. The magnetizing state of the
output relay is as follows:
At Non-Detection At Detection
Detect On OFF ON
Non Detect ON OFF
2. OFFSET Adjusting Trimmer An offset adjusting trimmer for noise
component
left ... larger right ... smaller
3. GAIN Adjustment Trimmer An adjusting trimmer for amplifying only
input signals
left ... smaller right ... larger
4. ON DELAY Adjusting Trimmer A time adjusting trimmer for ON DELAY
Max. setting time is approx. 7 seconds
5. OFF DELAY Adjusting Trimmer A time adjusting trimmer for OFF
DELAY. Max. setting time is approx. 7
seconds
6. LED Display The red LED (4 pieces) indicate the
intensity of input signals. When the LED
illuminate, the relay will be switched on.
1
6
5432
NON
DETECT
ZERO RY ON
DELAYDELAYGAINOFFSET
OFFON
DETECT