2. POWEr:SET [numeric value|MIN|MAX]
This command allows the user to set the output power of the AR2010 to a specified numeric value, the
minimum output power level, or the maximum output power level. The range of acceptable input power
values is dependent on frequency. If a specified input value cannot be reached, the AR2010 will automat-
ically set the power level to the next closest value. Power settings stay static across frequency changes;
therefore, if the power level is set to 5 dBm at 6 GHz, changing the frequency to 8 GHz will automati-
cally set the power level to 5 dBm. The same is true when the maximum or minimum value is set, but
note that the maximum output power at 5 GHz may be different from the maximum output power at 9 GHz.
Syntax
POWE :SET Space numeric value|MIN|MAX
?
Example
POWE:SET MAX This command sets the output power of the device to its maximum value
POWE:SET -10 This command sets the output power of the device to -10 dBm
Default Condition
On power up, or when a *RST command is issued, the AR2010 output power defaults to the power level
stored in the selected SYSTem:BOOTSTATE.
Query
POWE:SET? -5 (The output power of the device is currently -5 dBm. Neither MAX nor MIN has been
specified.)
POWE:SET? MAX,15 (MAX has been specified, and the maximum output power at the current fre-
quency is 15 dBm. The two values are separated by a comma.)
Error Messages
If the power entered is out of the operational range of the device, an error message of 201, "Parameter
specified out of Device’s operating range" is placed in the device’s error queue.
Applied Radar, Inc. Revision 2.0.1 27