User manual

AR2010 USB Stick Synthesizer User Manual
10. SYSTem:SAVESTATE [1-5]
This command saves the current setup to non-volatile memory. There are 5 re-writeable memory loca-
tions, specified by choosing an index between 1 and 5. Any of the 5 states can be restored on startup
when specified with the SYSTem:BOOTSTATE command. The parameters saved are the PLL mode, fre-
quency, reference divider, reference internal/external, reference frequency, max/min power setting, output
power, RF power (on AR2010-4400 models only).. For a detailed description of the parameters saved,
see your product’s Operation Manual.
Syntax
SYST :SAVESTATE Space 1-5
There are 5 memory locations, numbered 1 through 5. Memory location 0 contains the factory default
settings and is write-protected.
Example
SYST:SAVESTATE 3 This command saves the current state to memory location 3
Applied Radar, Inc. Revision 2.0.1 41