Specification

17 West Street | West Hatfield, MA 01088 | Toll Free 800.582.2213 | Phone 413.247.3380 | Fax 413.247.3369 | info@aptankless.com | www.aptankless.com
Model AQM 2-1
*
AQM 3-1 AQM 4-2 AQM 6-2
Item No. 612431 612433 612435 612436
Phase - 60/50 Hz 1
Voltage 120
v 120 v 240 v or 208 v 240 v or 208 V
Wattage 1.8 kW 3.0 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW
Amperage draw 15
a 25 a 14.6 a 12.7 a 23.8 a 20.6 a
Min. recommended circuit breaker size
1
15 a (sp) 25 a (sp) 15 a (dp) 15 a (dp) 25 a (dp) 25 a (dp)
Min. recommended wire size (copper)
2
14 awg 10 awg 14 awg 14 awg 10 awg 10 awg
GPM model is designed to deliver 0.32 gpm / 1.2 l/min 0.50 gpm / 1.9 l/min 0.66 gpm / 2.5 l/min 1.0 gpm / 3.8 l/min
Minimum water ow to activate unit 0.21
gpm / 0.8 l/min 0.40 gpm / 1.5 l/min 0.40 gpm / 1.5 l/min 0.77 gpm / 2.9 l/min
Weight 3.44 lb / 1.56 kg
Dimensions (H x W x D) 6 ½” / 165 mm x 7 ½” / 190 mm x 3 ¼” / 82 mm
Volume of water in unit 0.026 gal / 0.1 l
Working pressure 150 psi / 10
bar
Tested to pressure 300 psi / 20 BAR
Water connections
3 3
/
8
” O.D. flexible braided stainless steel hose connectors
AQM Series Technical Data
ISO 9001
CERTIFIED
Tested and certied by WQA against
NSF/ANSI 372 for lead free compliance.
Certied to ANSI/UL Std. 499
Conforms to CAN/CSA E335-1
and E335-2-35
*
AQM 2-1 is internally restricted to 0.32 GPM / 1.2 l/min.
AQM 2-1, 3-1 ship with a 0.5 GPM pressure compensating ow-reducer/aerator that must be installed.
AQM 4-2 ships with a 0.66 GPM pressure compensating ow-reducer/aerator that must be installed.
AQM 6-2 ships with a 1.0 GPM pressure compensating ow-reducer/aerator that must be installed.
1
This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heaters are considered a non-continuous load.
2
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
3
Suitable for supply with cold water only.