User Model

AIR CONDITIONER FEATURES
Displays
Shows the set temperature in C or F and the
Auto-timer settings.While on Fan only mode,it shows
the room temperature.
" " " "
O O
DISPLAYS:
-
HS -
Evaporator temperature se nsor error-Unplug the
unit and plug it back i n.If error repeats , call for
service.
NOTE : is displayed as shown in t he left pic ture.
Electric heati ng sensor error-Unp lug t he unit and
plug it back in.If error repeats, call for servic e.
" "
Error codes:
AS-Room temp erature sensor error-Unplu g the unit
and plug it b ack in.If error repeats, ca ll for service.
NOTE: In Fan o nly mode,it will disp lay LO or HI ." " " "
If the unit breaks off unexpectedly due to the power
cut, it will restart with the previous function setting
automatically when the power resumes.
DISPLAYS:
NOTE:
Air Directional Louvers
ADDITIONAL TH INGS YOU SHOULD KNOW
Now that you have mastered the operating procedure,
here are more features in your control that you should
become familiar with.
The Cool circuit has an automatic 3 minute tim e
delayed start if the unit is turned off and on quickly.
This prevents overheating of the compressor and
possible circuit breaker tripping.The fan will
continue to run during this time.
The control is capable of displaying temperature in
degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Left and
Right Temp/Timer buttons at the same time, for 3
seconds.
CARE AND CLEANING
CAUTION
Clean your air conditioner occasionally to keep it looking
new. Be sure to unplug the unit before cleaning to
prevent chock or fire hazards.
Air Filter Cleaning
The air filter should be checked at least once a month to see
if cleaning is necessary. Trapped particles in the filter can
build up and cause an accumulation of frost on the cooling
coils.
15
Exhaust Control
S
Exhaust
close d
open
Mode
Ener gy
Saver
Tim er
on
Tim er
off
A uto Coo l Dry Fan
This Exhaust Control allows the air conditioner to
either circulate inside air (Closed) or exhaust air to
the outside (Open).
The Closed position is used when maximum cooling
is desired. It may also be used for air recirculation
without cooling when the air conditioner is set in any
FAN position.
The Open position removes stale air from the room
and exhausts it to the outside. Fresh air is drawn in
through normal passages in the home.
4-Way Louvers
The 4-Way air directional louvers allow you to
direct air flow up or horizontal, left or right
thr oughout the room as needed. To adjus t the
air directional louvers side-to-side, use the center
handle as you move it side-to-side.