Specifications

13
ø19.05
ø38.1
ø19.05
ø31.75
ø15.88
ø28.58
ø12.7
ø25.4
ø9.52
ø19.05
ø9.52
ø15.88
ø9.52
ø12.7
(mm)
(mm)
70.0
(25 hp)
42.0
(15 hp)
ø12.7
ø28.58
52.4
(19 hp)
42.0
(15 hp)
7.1
(2.5 hp)
7.1
(2.5 hp)
98.0
(35 hp)
98.0
(35 hp)
16.0
(6 hp)
16.0
(6 hp)
70.0
(25 hp)
22.5
(8.1 hp)
ø9.52
ø22.22
22.5
(8.1 hp)
30.0
(11 hp)
30.0
(11 hp)
Below kW
Over kW
42.0
(15 hp)
Total capacity
after distribution
Tubing size
Wide tubing
Narrow tubing
hp = horsepower
Unit: mm
1-5. Tubing Size
Table 1-11a Main Tubing Size (LA)
Unit: mm
10
12
34
10
10
32
10
10
85.0
30
8
10
78.5
28
8
8
73.0
26
ø9.52
ø22.22
10
28.0
33.5
12
ø25.4
ø12.7
14
40.0
88
45.0
16
ø28.58
ø15.88
18
50.4
8
10
56.0
20
ø19.05
ø31.75
22
61.5
10
12
68.0
24
22.4
8
ø19.05
ø9.52
ø9.52
ø19.05
6
16.0 90.0
10
12
10
10
10
10
12
10
12 12
12
121010
101.0 106.5 113.0 118.0
40 42
ø38.1
44
10
46
ø19.05
12
48
12
135.0
130.0123.5
38
10
36
810
––
96.0
(6) (8)
(10) (12) (12)(10)(10)(10) (12)(10)
(6)
(12) (12)
(12) (12)(10) (10) (12) (12) (12)
(8)
(10)
kW
kW
Total system
horsepower
Total system
horsepower
Combined
outdoor units
Combined
outdoor units
Wide tubing
(mm)
Wide tubing (mm)
Narrow tubing
(mm)
Narrow tubing (mm)
Table 1-12 Outdoor Unit Tubing Connection Size (
A
D
) Unit: mm
22.5
ø9.52
22.4
16.0
ø22.22
ø9.52
22.4 28.0 33.5
28.1
28.0 33.5
33.6
ø19.05
ø12.7
ø25.4
ø19.05
ø22.22 ø25.4
ø9.52 ø12.7
Brazing connection
Brazing connection
Brazing connection
Brazing connection
ø9.52
Flare connectionFlare connection
Wide tubing
Balance
tubing
Main unit (DC inverter unit)
Sub unit (constant speed unit)
kW
Narrow tubing
Note 1: (6), (8), (10), (12) in the combination table indicate the horsepower of the main units (DC inverter type). 8, 10, 12
indicate the horsepower of sub units (constant speed type).
2: If future extension of the system is expected, select tubing diameters that are based on total horsepower after extension.
However, extension that requires increasing the tubing size by 2 steps is not possible.
3: The balance tubing (outdoor unit tubing) size is
φ9.52.
Size of tubing (LO1, LO2) between outdoor units
Select the size of tubing between outdoor units based on the main tubing size (LA) as given in the table above.
Table 1-11b Main Tubing Size After Distribution (LB, LC...)
Note: 1. In case the total capacity of connected indoor units exceeds the total capacity of the outdoor units, select the main
tubing size for the total capacity of the outdoor units. (Especially the main tubing segments of LA, LB and LF.)
04-396 Inverter-W_a-p50 ARGO 12/21/04 9:38 AM Page 13