3-7. Installing the Drain Piping
(1) Prepare standard hard PVC pipe (O.D. 32 mm) for
the drain and use the supplied drain hose and hose
band to prevent water leaks. The PVC pipe must be
purchased separately. The units transparent drain
port allows you to check drainage. (Fig. 3-26a)
CAUTION
Fig. 3-26a
Fig. 3-26b
Drain hose
(supplied)
(not supplied)
(not supplied)
Packing (supplied)
VP-25
Align the hose band with end of the
hose, and tighten so that it does not
contact the bead.
Drainage check
section on drain port
(transparent)
Hard PVC
socket VP-25
Hard PVC
pipe
PVC adhesive
Bead
Vin
y
l clamps
Drain insulator (supplied)
(2) After checking the drainage, wrap the supplied
packing and drain pipe insulator around the pipe,
then secure it with the supplied clamps. (Fig. 3-26b)
Make sure the drain pipe has a downward gradient
(1/100 or more) and that there are no water traps.
NOTE
Do not use adhesive at the drain connection
port on the indoor unit.
Insert the drain pipe until it contacts the sock-
et, as shown in the figure at right, then secure
it tightly with the hose band.
Tighten the hose clamps so their locking nuts
face upward. (Fig. 3-26a)
Do not use the supplied drain hose bent at a 90°
angle. (The maximum permissible bend is 45°.)