Technical information

8
VIEW OF THE BOILER CONNECTIONS
LEGEND:
A = Central Heating Flow
B = Domestic Hot Water Outlet
C = Gas Inlet
D = Domestic Cold Water Inlet
E = Central Heating Return
F = Condensate discharge
G = Drain valve
H = Safety Valve Outlet
2.8 WA
TER
CO
NNECTIONS
2.7 GAS CONNECTION
The local gas region contractor connects the gas meter to
t
he service pipe.
If the gas supply for the boiler serves other appliances
ensure that an adequate supply is available both to the
boiler and the other appliances when they are in use at
the same time.
Pipe work must be of an adequate size. Pipes of a
s
maller size than the boiler inlet connection should not be
used.
FIG. 2.4
F
IG. 2.5
KT007A
CENTRAL HEATING
Detailed recommendations are given in BS 6798:2000
and BS 5449-1:1990, the following notes are given for
general guidance.
PIPE WORK:
Copper tubing to BS EN 1057:1996 is recommended for
water pipes. Jointing should be either with capillary
soldered or compression fittings.
Where possible pipes should have a gradient to ensure
air is carried naturally to air release points and water
flows naturally to drain taps.
The appliance has a b
uilt-in automatic air release v
alve,
however it should be ensured as far as possible that the
appliance heat exchanger is not a natur
al
collecting point for air.
Except where providing useful heat, pipes should be
insulated to pre
v
ent heat loss and a
void freezing.
Particular attention should be paid to pipes passing
through ventilated spaces in roofs and under floors.
BY-PASS:
The appliance includes an automatic by-pass valve,
which protects the main heat e
xchanger in case of
reduced or interrupted water circulation through the
heating system, due to the closing of thermostatic valves
or radiators.
SYSTEM DESIGN:
This boiler is suitable only for sealed systems.
DRAIN COCKS:
These must be located in accessible positions to permit
the draining of the whole system and should be fitted at
all low points. The taps must be at least 15mm nominal
size and manufactured in accordance with BS 2870:1980.
A
B
C
D
E
G
F
H