Installation Guide

Before You Begin
Store and install ceilings in areas with a temperature range of 60° to 85° F
and not more than 70% relative humidity.
Remove ceiling planks from cartons 24 hours before installation and allow
to adjust to normal interior conditions of the installation area.
Do not apply loose fill or batt insulation so that it rests directly on the back
of the planks.
Do not install ceiling tiles below imbedded radiant-heat coils.
Keep hands clean during tile installation to avoid fingerprints and smudges.
Handle ceiling planks carefully to protect the face and edges from damage.
Always cut ceiling tiles face up with a sharp utility knife.
For Adhesive Applications of mineral fiber only
planks directly to existing
drywall or plaster ceilings: Ceiling tile adhesive recommended, such as
Henry 237 AcoustiGum™ Acoustical Ceiling Tile Adhesive. Please follow
adhesive manufacturer’s instructions for application and usage. Armstrong
does not guarantee the performance of this or other adhesive products,
either alone or in conjunction with Armstrong products.
Maintenance
Hints
Remove dust and loose dirt with a soft brush or vacuum hose with a soft
brush attachment.
Remove pencil marks, small smudges, or clinging dirt with an ordinary
art-gum eraser.
Wash with a damp sponge, mild soap and lukewarm water if necessary. Do
not soak tiles with water.
Tools &
materials
you may
need
Safety
Establish and maintain adequate ventilation in the work area. If high dust
levels are anticipated during installation, such as with the use of power tools,
use an appropriate NIOSH-designated dust respirator. All power cutting tools
must be equipped with dust collectors.
Wear long-sleeve, loose fitting clothing and gloves.
Persons who are sensitive to odor and /or chemicals should avoid the
work area during this process.
Wear safety glasses to minimize the risk of eye injury.
Use a sharp utility knife to ensure clean cuts. When not in use, store
properly.
Safety Glasses
Tape Measure
Straight Edge
Hammer
Pencil
#6 Course Thread
Drywall Screws
4’ Carpenter's
Level
Utility Knife
Stud Finder
Hacksaw
Dust Mask
Drill/Screw Gun
Gloves
Tin
Snips
String
Chalk
Line
Screw Driver
1
Determine border tile size for a
balanced appearance:
1. Measure room length in same direction as track
2. Divide by 6"
3. Multiply the remainder by 6"
4. Add 6" to the result
5. Divide result by 2
6. Record your border plank width
EXPOSED
JOISTS
PLASTER CEILING
OR DRYWALL
Locate ceiling joists
Tap on the plaster or drywall ceiling until you hear a solid thud, or use a stud finder. Generally, joists
are spaced 16" or 24" on center.
EXAMPLE:
Room = 170"
170"÷6" = 28.333
0.333 x 6" = 2"
2"+ 6"= 8"
8"÷ 2 = 4"
Border plank width = 4"
CALULATE
YOUR ROOM:
4"
Joist Direction
4"
170"
S
I
D
E
W
A
L
L
TRACK
JOIST
TRACK
Begin Installation
INSTALLATION OF MINERAL FIBER PLANKS USING THE EASY UP
®
INSTALLATION SYSTEM OR ADHESIVE
Easy Up
Track
Easy Up
Clip
Item #1191
Item #1190
We are constantly working to improve our instructions with learnings from customers like you. For the
most up-to-date instructions, please visit ceilings.com/installation. If you need additional guidance, call our
Techline at 1-877-ARMSTRONG.