User Manual October 2016
© 2015 - 2016 Arnold & Richter Cine Technik GmbH & Co. Betriebs KG (ARRI). All rights reserved. Information subject to change without notice. ARRI and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document.
SkyPanel S30 (manual version) Dimensions Dimensions 3
Dimensions 4 SkyPanel S30 (P.O.
Dimensions SkyPanel S60 (manual version) 5
Dimensions 6 SkyPanel S60 (P.O.
Dimensions SkyPanel S120-C (manual version) 7
Dimensions 8 SkyPanel S120-C (P.O.
Content Content Dimensions ..................................................................................................................................................... 3 Safety Information ........................................................................................................................................ 11 Replacing the Light Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Content 10 Error Codes .................................................................................................................................................. 51 ARRI Lighting Service Manager .................................................................................................................. 52 Protocol ......................................................................................................................................................... 53 Specification ..........
Always follow these instructions and instructions printed on the product or given in the documentation shipped with the product to protect against injury to yourself and damage to the product or other objects. Explanation of Warning Signs and Indications Possible risk of injury or damage to equipment. Risk of fire or electric shock. Possible risk of injury or death or damage to equipment. Caution! Hot surface. Possible high surface temperature. Risk of injury through burns.
Safety Information General Safety Information Read and understand all safety information and operation instructions before you operate or install the product or the system. Use only genuine spare parts or accessories that have been recommended or approved by ARRI. Other accessories or spare parts may cause hazards, damage the product or invalidate the warranty. Check all cables and devices for visible damage before you work with the system. Defective electric or electronic devices must not be used.
Not to observe the safety information or general rules of reason may cause injury or death to yourself and others or damage to equipment. Intensive use can cause the surface to become warm. Let the product cool down complete before you handle it. Never cover air vents during operation. Keep a minimum clearance around the air vents of 0.5 m (1.65 ft.). WARNING: Intense light. Do not stare at the operating light source. Keep a minimum distance to an illuminated surface, object or person of 1.0 m (3.3 ft).
Safety Information CAUTION: High voltage! Danger of life! Always disconnect the product complete from mains voltage before you connect or disconnect a cable. Maintenance Information • Do not clean the surface of the product with solvents or strong detergents. Always keep cables away from the product during operation. Do not tilt the power cable directly after the connector. Water could immerse and cause short circuits and damage the connector.
Thank you for selecting the SkyPanel LED softlight from ARRI. The SkyPanel is a compact, ultra-bright and high-quality LED softlight. It is much more efficient than a softlight with a conventional light source. The SkyPanel combines the advantages of the LED technology with the characteristic of a conventional softlight. The SkyPanel integrates seamless into established working practice. Lighting designers as well as Studios don’t need to change its workflow.
Introduction Properties Unpacking Guiding Rails Diffuser plates and other accessories for shaping the light like a barndoor are inserted in the locking guiding rails at the front of the fixture. The SkyPanel is supplied with: Stirrup The stirrup provides high strength with minimum weight. The external power supply unit can be mounted on the stirrup. An optional, pole operated yoke allows full operation of pan and tilt from the floor and is therefore a popular choice for many studios.
Overview Overview Fixture menu Manual Version Handle Spigot Stirrup Tilt lock Top latches Diffusor or remote phosphor panel Connector panel Tilt lock lever Figure 1: Front and back view, manual version (the figure shows the S60) 17
Overview P.O. Version Fixture menu Handle Top latches Spigot Stirrup Diffusor or remote phosphor panel Connector panel Figure 5: Power supply unit S30 Figure 2: Front and back view, P.O. version (the figure shows the S30) 18 P.O.
Overview USB-A port DMX In Boot mode DMX Thru Ethernet connector Power in 48 V = Battery in 23 - 36 V = Figure 3: Connector panel 19
Overview Power Supply Unit S60 / S120 Power Supply Unit S30 Front panel Power out 48 V = Main switch Back panel Power out 48 V = Power in and thru Main switch Power in and thru Figure 4: Power supply unit S60 / S120 20 Figure 5: Power supply unit S30
WARNING! Attach an approved safety-cable to secure the product and accessories against clamp or bracket failure when the product is mounted above floor. The safety-cable needs to be approved at least 10 times the weight of the product including all accessories mounted at the product. The safety cable must comply with EN 60598-2-17 Section 17.6.6 and be approved by an official body such as TÜV. Lead the safety-cable through the stirrup and keep it as short as possible.
Physical Installation To Mount the Stirrup • Place the SkyPanel with the lighting aperture facing downwards on an even and clean surface. • Remove two allen screws (4 mm allen key) on each side of the product. • Insert both connector elements on both sides of the stirrup into the holder on each side of the SkyPanel (see Figure 6). • Mount the stirrup with two allen screws on each side of the product (4 mm allen key, recommended torque: 5 ft-lb.).
• Both guiding rails are locked. • Tripods are set up in a stable position. Tripods need to be approved for the load they need to carry. Always observe the additional load of cables and accessories! Physical Installation To Install the SkyPanel Always observe all safety information given above when mounting the SkyPanel and accessories.
Basic Features Basic Features Pan and Tilt Loose the mounting screw of the tripod or the appropriate fixing screw of the mounting clamp to pan the SkyPanel. Tighten the screw to avoid unintended movement. Loose the tilt-lock to tilt the SkyPanel to the desired angle. Tighten the tilt-lock-lever to avoid unintended movement. Use of Accessories for Beam Shaping You can mount accessories using the guiding rails on the front side of the SkyPanel: both safety catches snap in.
USB-interface Note: Disconnect all DMX cables from the product before using an USB memory stick. The data transfer between the product and the USB memory stick might be disturbed due to interferences. The SkyPanel has an USB-A connector to upload firmware, upload and download fixture settings and preset lists or download error and service logs using an USB memory stick. The memory stick must be formatted with the FAT32 file system.
To Power the SkyPanel To Power the SkyPanel WARNING! Use only an ARRI power supply unit and an ARRI connector cable. The use of other power supply units and connector cables might cause malfunction and damage of the product. WARNING! For protection from electric shock, always connect the external power supply unit electrically to ground (earth) when connected to AC power. The AC mains power supply must be fitted with a fuse or circuit breaker and ground-fault (earth-fault) protection.
• Turn the cable connector a full quarter-turn clockwise to lock the cable connector. • To unlock the cable connector, push the connector lock backwards and turn the cable connector counter-clockwise. Pull the cable connector out of the power input socket.
To Power the SkyPanel The product has a 4-pin XLR male connector for battery power and DMX data input. The pin-out is: Pin Assignment 1 0V 2 n.c. 3 n.c. 4 + 23 V - 36 V= IMPORTANT! Check that the pin-out of the battery pack matches the pin-out of the product. Wrong assigned pin-outs damage the SkyPanel and / or the battery pack. Always follow the safety information for the battery pack. Use only battery packs that meet all requirements listed above.
DATA-LED (2): Overview 10 11 9 8 1 2 3 Color Indication Blue The fixture receives a valid DMX signal. Purple Master mode active White Receiving valid Art-Net signal, Gateway active Green Receiving valid Art-Net signal, Gateway not active Red No communication between fixture menu and controller board. No light The fixture receives no valid control signal.
Fixture Menu INTENSITY/SELECTOR (I/S, 4) The INTENSITY/SELECTOR encoder I/S has two functions: • Fixture menu closed: Setting the intensity. • Fixture menu open: Use I/S to scroll through the menu, open sub menus and set parameters. Pressing the knob opens sub menus and confirms settings. Central Rotary Knob (5, only SkyPanel-C) Use the rotary knob to set the color temperature (CCT) or the color hue (HUE). The current function of the rotary knob is shown in the display (9) above the knob.
In CCT mode the SkyPanel generates white light with optimized color rendition. In HSI mode the SkyPanel generates colored light. If saturation is set very low, the SkyPanel generates white light, but not with optimized color rendition. The GEL mode offers an extensive color gel library. To set the Color Temperature and Green / Magenta Saturation in CCT Mode (only SkyPanel-C) Set the color temperature continuously with the central rotary knob (5).
Fixture Menu • Logarithmic: The resolution is low at lower intensity levels and high at higher intensity levels. Use this dimming curve when you need a high resolution at high intensity levels. • „S“ curve: The resolution is both high at lower and higher intensity levels and low at intensity levels in between. Use this dimming curve, when you need a high resolution at low and high intensity levels. To set the dimming curve: • Press the MENU button (10) to open the fixture menu.
Connect a maximum of 32 SkyPanels and L-series fixtures to a DMX data link. Choose one SkyPanel to be the master fixture. Warning! There must not be more than one SkyPanel in the data link set to master. Setting more than one fixture to master or connecting a DMX controller to the data link causes one or all master fixtures to de-activate the master mode and display an error message (error 25). Please note when using the master/slave mode: • Art-Net is de-activated on all fixtures in the data link.
Fixture Menu • Turn I/S, until „DMX Settings“ is displayed. Press I/S to open the menu. • Turn I/S, until „DMX Protocol“ is displayed. Press I/S to open the menu. Option Description Hold for 2 min. then fade out The last received DMX values are used for 2 minutes. After 2 minutes the fixture douses to 0% intensity. When valid DMX data is received after less than 2 minutes, these data will be used. • Select the DMX mode by turning I/S. Press I/S to confirm the setting.
• Turn I/S, until „Lighting Effects“ is displayed. Press I/S twice to open the menu. • „Party Effects“ activates a stand-alone demo sequence, „Off“ de-activates the demo sequence. The demo sequence calls up the color spectrum or changes the color temperature from warm to cold and vice versa in an endless loop. Set the intensity with I/S. Set the speed with the central rotary knob from 0-100% (60 s - 1 s). The right rotary knob sets the saturation and changes between color and color temperature sequence.
Fixture Menu To save and load a Preset List Note: Disconnect all DMX cables from the product before using an USB memory stick. The data transfer between the product and the USB memory stick might be disturbed due to interferences. The fixtures preset list can be saved to an USB memory stick and uploaded to another SkyPanel. To save a preset list: • Connect an USB memory stick to the USB-A connector of the SkyPanel. • Press the MENU button (10) to open the fixture menu.
and service log to the ARRI service. The log files can be downloaded to an USB memory stick. • The fixture settings will be saved on the USB memory stick. The file name contains the date, time and serial number of the fixture. Up to 30 fixture settings files can be stored in the root directory of the USB memory stick. The file name is -Clonexx.json. The SkyPanel is looking for „Clonexx.json“ to identify a fixture settings file on an USB memory stick.
Fixture Menu To Perform a Factory Reset • Press the MENU button (10) to open the fixture menu. • Turn I/S, until „Factory Reset“ is displayed. Press I/S to open the menu. • Turn I/S to choose the option „Yes“ and perform a factory reset. Press BACK (11) to abort. • The SkyPanel reboots with its factory settings.
The SkyPanel offers, depending on the model, up to 19 control modes. Use the 8 bit modes (mode 1 and 2) with basic controllers like dimmer consoles. ARRI recommends the use of the 16 bit modes in combination with controllers supporting 16 bit resolution to obtain best results. The high resolution provides smooth dimming and precise color adjustments.
Art-Net Art-Net From firmware version 2.0 the SkyPanel supports Art-Net. ArtNet is a network protocol for controlling devices. Art-Net supports all modes of the SkyPanel. Here is a brief explanation of some basic terms being used by Art-Net. For more detailed information, please visit the web site of the Art-Net developers: www.artisticlicence.com. Art-Net IP Address When setting the IP address manually, please take care the address is in the range 2.0.0.1 to 2.255.255.255 (Network switch off) or 10.0.0.
Tips for a Reliable Data Transmission To control the SkyPanel via DMX you need a DMX data link. The SkyPanel has 5-pin locking XLR sockets for DMX / RDM data input and output. The default pin-out of both sockets is: • Use shielded twisted-pair cable designed for RS-485 devices or CAT 6 network cables. Standard microphone cable cannot transmit control data reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters (1000 ft.).
Fixture Menu Fixture Menu From firmware version 2.5 Note: Open and close the fixture menu the MENU button. BACK closes a sub menu and aborts an action. Rotate INTENSITY / SELECTOR to scroll.
Level 2 Level 3 Level 4 Exponential Dimming Curve Light Control Linear dimming curve Logarithmic Logarithmic dimming curve „S“ Curve Combination of exponential and logarithmic dimming curve Special Modes Tungsten Mode Lighting Effects Exponential dimming curve Linear Low End Mode Master/ Slave Mode Explanation (default setting = bold) Off Flicker free light On Optimized dimming behavior at low intensity levels Off Color temperature optimized when dimming On Emulates the behavior of a
Fixture Menu Level 1 Level 2 Display Illumination Level 3 Level 4 Always On Display illumination always on Off After 10 Sec. Display illumination douses 10 sec.
Level 2 Level 3 Art-Net Net 0 - 127 Select Art-Net net (see page 40) Art-Net Subnet 0 - 15 Select Art-Net subnet in Art-Net net Art-Net Universe 0 - 15 Select Art-Net universe in Art-Net subnet Art-Net Merge Mode Art-Net Settings Art-Net State Level 4 Explanation (default setting = bold) LTP Select Merge-Mode „LTP“ (Last Take Precedence) HTP Select Merge-Mode „HTP“ (High Take Precedence) Disabled Art-Net disabled Enabled Art-Net enabled Off Gateway disabled On Gateway enabled (see p
Fixture Menu Level 1 Level 2 Level 3 Low Battery Warning 23.0 - 24.1 - 36.0 V Low Battery Warning Voltage (see page 35) DHCP Use DHCP mode Art-Net 2.B.C.D Use Art-Net net 2.B.C.D IP Mode Fixture Settings 46 Explanation (default setting = bold) Art-Net 10.B.C.D Use Art-Net net 10.B.C.D Manual Jumps to „IP Address“ (see page 40) IP Address AAA.BBB.CCC.
From firmware version 2.0 Command Description GET SET Discover Unique Branch Searches RDM device X X Discover Mute Mutes the RDM device, no response messages X X X Discover Unmute Activates device for response messages X Supported Parameters Shows a list of all supported RDM commands X Parameter Description Shows a list of commands that are not standard rdm commands, mostly commands from manufacturer.
RDM commands 48 Required RDM command extensions Command Description GET Status Message Display of actual warning / error message of the fixture. X Status ID Description Detailed description of each warning / status report. X Device Label This parameter allows you to generate an informative label for each fixture.
Description GET Lamp Hours Shows the actual lamp hours of the fixture X SET Factory Defaults This command deletes all user parameters and sets the fixture to factory default X Device Power Cycles Shows the power cycle value, counts every cold start (switch or power-up) X X Reset Device Fixture makes a software reset (warm start) and carries out a reboot X X Power State Power state of the fixture, supported power states: POWER_STATE_STANDBY (0x02), POWER_STATE_NORMAL (0xFF), POWER_STATE_FUL
RDM commands Command GET SET If the DMX signal gets lost or the DMX device is unplugged the LED fixture holds the last valid signal, or it holds the last valid signal for two minutes and then douses or switches off immediately.
Code Error Remedy E.003 Controller over temperature. STATUS LED lit up red. Let the SkyPanel cool down. The STATUS indicator changes to green when the SkyPanel has cooled down. Turn the dimmer knob to „0“ or send an intensity value „0“ via DMX to activate the light engine again. E.004 Light engine over temperature See E.003 E.005 Missing LED supply. The LED power supply is faulty. Please contact the ARRI service. E.006 Calibration data of light engine faulty or EEPROM error.
ARRI Lighting Service Manager Code Error Remedy E.0016 Boost over temperature Let the SkyPanel cool down. The STATUS indicator changes to green when the SkyPanel has cooled down. Turn the dimmer knob to „0“ or send an intensity value „0“ via DMX to activate the light engine again. E.017 Battery voltage too low Battery voltage below 20.5 V. Change the battery pack or switch to AC power. E.018 PWM driver not found Switch the SkyPanel off and on again.
Mode 2: 16 bit Resolution per Function Protocol V4.2 is set as default. Use the ALSM to change to Protocol V4.1 or V3.4. ARRI recommends to reserve 4 channels more for each fixture when using Protocol V3.4. This way you do not need to change the patch when you want to use additional features which will become available with Protocol V4.2. The Protocol V4.2 uses 4 Channels more. SkyPanel-RP From Firmware-Version 2.
Protocol SkyPanel-C Mode 1: CCT & RGBW, 8 bit Resolution per Function From Firmware-Version 2.
Channel 1 2 3 4 Reverts to fixture setting when signal lost. 5-7 Value Percent Function 0-255 0-100 Master Intensity 0 % 100% (open) 0-255 0-100 Color temperature CCT 2.800 K 10.000 K 0-10 11-20 21-119 120-145 146-244 245-255 0-4 5-8 8-46 47-57 57-96 96-100 GN saturation neutral / no effect full minus green -99% -1% neutral / no effect 1% 99% full plus green 0-9 10-60 61-120 121-180 181-250 251-255 0-4 5-23 24-47 48-70 71-98 99-100 Fan Control No function Low Variable High Fan max.
Protocol Mode 4: RGBW, 8 bit Resolution per Function Channel 1 2 3 4 5 6 Reverts to fixture setting when signal lost.
5 HI 6 LO 7 HI 8 LO 9 HI 10 LO 11 HI 12 LO 13 HI 14 LO Value Percent Function 0-5.000 5.001-10.000 10.001-29.999 30.000-40.000 40.001-59.999 60.000-65.535 0-7 8-15 16-46 46-61 61-92 92-100 GN saturation neutral / no effect full minus green -99% -1% neutral / no effect 1% 99% full plus green 0-65.535 0-100 Xfade to color white RGBW color 0-65.535 0-100 Intensity red 0% 100% 0-100 Intensity green 0% 100% 0-65.535 0-100 Intensity blue 0% 100% 0-65.
Protocol Mode 8: CCT & HSI, 16 bit Resolution per Function Channel 1 HI 2 LO Percent Function Channel 0-65.535 0-100 Master Intensity 0 % 100% (open) 1 HI 2 LO 3 HI HI LO 0-65.535 0-100 Color temperature CCT 2.800 K 10.000 K 3 4 4 LO HI HI 0-5.000 5.001-10.000 10.001-29.999 30.000-40.000 40.001-59.999 60.000-65.
Channel 1 HI 2 LO 3 HI 4 LO 5 HI 6 LO 7 Reverts to fixture setting when signal lost Value Percent Channel 0-4 5-8 8-46 47-57 57-96 96-100 0-255 0-100 Xfade to color white RGBW color 0-255 0-100 Intensity red coarse 0% 100% 0-255 0-100 Red fine 0-255 0-100 Intensity green coarse 0% 100% 0-255 0-100 Green fine 0-255 0-100 Intensity blue coarse 0% 100% 0-255 0-100 Blue fine 0-255 0-100 Intensity white coarse 0% 100% 14 0-255 0-100 White fine Color tempera
Protocol Mode 12: CCT, Coarse / Fine per Function Channel Value 0-100 0-255 0-100 Master Intensity fine 0-255 0-100 CCT coarse 2.800 K 10.000 K 0-255 0-100 CCT fine 0-4 5-8 8-46 47-57 57-96 96-100 GN saturation neutral / no effect full minus green -99% -1% neutral / no effect 1% 99% full plus green 5 0-10 11-20 21-119 120-145 146-244 245-255 7 0-4 5-23 24-47 48-70 71-98 99-100 Fan Control No function Low Variable High Fan max.
Channel 1 2 3 4 5 6 7 8 9 10 11 Reverts to fixture setting when signal lost.
Protocol Overview of typical CCT values as DMX values CCTvalue DMX-value (8 bit) Mode 16: GEL, 8 bit per function, Base channels DMX-value (16 bit) 1 Skypanel C C 3.200 K 14 3.670 5.600 K 99 25.493 6.000 K 113 29.098 6.500 K 131 33.685 To calculate CCT values in DMX % and vice versa Use the following formulas to transform CCT values in DMX % values and vice versa: CCT Target 2 3 CCT values SkyPanel-C CCTmin = 2.800 K CCTmax = 10.
6 7 8 9 Value Percent 0-100 Gel 1 See tables below 0 - 255 0 - 100 Xfade to Gel Gel 1 Gel 2 0-128 129-255 0-50 51-100 Gel 2,CCT Selection 3.200 K 5.600 K 0-128 0-50 129-170 51-67 171 - 255 68 - 100 Gel 2, Color Matching Best Color Color quality optimized Brightest Color brightness opt. No Color Gel 0-50 51-100 Gel 2, Brand Category on ch. 11 Gel on ch.
Protocol Mode 17: GEL, 16 bit per function, Base channels Channel 1 HI 2 LO 3 4 Value Percent 0-65.535 0-100 Master Intensity 0 % 100% (open) 0-128 129-255 0-50 51-100 Gel 1,CCT Selection 3.200 K 5.600 K 0-128 0-50 129-170 51-67 171 - 255 68 - 100 Gel 1, Color Matching Best Color Color quality optimized Brightest Color brightness opt. No Color Gel 0-50 51-100 Gel 1, Brand Category on ch. 5 Gel on ch.
Value 14 Percent 0-255 0 – 51 52 – 102 103 – 153 154 – 204 205 - 255 15 16 Reverts to fixture setting when signal lost. 0-100 0 – 20 21 – 40 41 – 60 61 – 79 80 - 100 0-9 10-60 61-120 121-180 181-250 251-255 0-4 5-23 24-47 48-70 71-98 99-100 17-19 Category 1, Rosco, Color correction, continued Function Gel 2 See tables below Chan.
Protocol 66 Category 2, Rosco, CalColor Category 3, Rosco, Storaro Selection Chan.
Category 1, LEE Color Correction Chan.
Protocol Category 1, LEE Color Correction, continued Category 2, LEE Color Filters, continued Chan. Value Gel name Number 6 68 - 69 70 - 71 72 - 73 74 - 75 76 - 77 78 - 255 1/8 Plus Green LEE Minus Green 1/2 Minus Green 1/4 Minus Green 1/8 Minus Green Reserved 278 247 248 249 279 Chan.
Category 3,LEE 600 Series Chan.
Protocol 70 Category 5,LEE 700 Series Category 5,LEE 700 Series, continued Chan.
Channel 1 2 3 4 5 6 7 8 Reverts to fixture setting when signal lost. 9-11 Value Percent Function 0-255 0-100 Master Intensity 0 % 100% (open) 0-255 0-100 X1 Coordinate 0.0 0.8 0-255 0-255 0-255 0-255 0 – 51 52 – 102 103 – 153 154 – 204 205 - 255 0-9 10-60 61-120 121-180 181-250 251-255 Mode 19: xy Coordinates, 16 bit Resolution per Function Channel 1 HI 2 LO 3 HI 4 LO 5 HI LO 0-100 Y1 Coordinate 0.0 0.8 6 0-100 Xfade X1, Y1 X2, Y2 7 HI 0-100 X2 Coordinate 0.0 0.
Specification Specification Physical, SkyPanel S30 Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 mm (5.2 in.) Wide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507 mm (19.9 in.) Height . . . . . . . . . . . . . . . . . . . . . . . . 347 mm (13.6 in., w/o stirrup) Weight (w/o accessories) . . . . . . . . . . 8 kg (17.6 lbs), 9 kg (20 lbs) Physical, SkyPanel S60 Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 mm (5.2 in.
Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blue / silver or black Housing . . . . . . . . . . . . . . . . . . . . . . . . . Composite and aluminum Protection rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 20 Protection class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . III Installation Mounting. . . . . . . . . . . 28 mm spigot or 16 mm / 28 mm combo pin Orientation . . . . . . . . . . . . . . . . . . . . . +/- 90° Min.
Specification 74 Order Information All versions include Power supply unit (PSU) Rail mount adapter for SkyPanel PSU (not with Center Mount) Standard diffusion panel (only C-Version) Manual and Center Mount versions include additional Yoke with 16 mm / 28 mm combo pin (manual version) DC header cable 48 V= (XLR 3-pin), l = 3 m (10 ft) PowerCON TRUE1 mains cable, l = 3 m (10ft) with mains connector Center mount yoke (Center Mount version) P.O.
V-Mount Battery adapter plate . . . . . . . . . . . . . . . . . . . L2.0008070 Center mount yoke . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008078 Fixed center mount yoke . . . . . . . . . . . . . . . . . . . . . . . L2.0008080 Rail mount adapter for SkyPanel PSU . . . . . . . . . . . . . L2.0008082 Super clamp adapter for SkyPanel PSU . . . . . . . . . . . L2.