Brochure

NOTE
u
:
ALL POWER SUPPLIES SHOWN ARE 115 VAC - 1Ø - 60 Hz.
NOTE
v
:
POWER REQUIREMENTS FOR ARTP-32 AND ARTP-36 INCLUDE
LIGHTAND ROTISSERIE POWER TOGETHER.
AAEP BBQ'S USE
9 VDC INGNITION AND DO NOT HAVE LIGHTS.
NOTE
w
:
ALL GAS LINES REQUIREMENTS ARE AS FOLLOWS:
NG:
1/2" NPT WITH 5" W.C.
LP:
3/8" ODF WITH 10" W.C.
NOTE
x
:
INSULATED JACKETS ARTIJ-26 / 32 / 36 DO NOT REQUIRE POWER
AND/OR GAS LINES BY THEMSELVES. ONLY THE GRILLS THEY ARE
MEANT TO INSULATE REQUIRE THEM.
NOTE
y
:
ART-SB1 GAS LINE IS 3/8" OD CONNECTED TO THE EXISTING GRILL
WITH SUPPLIED GAS FITTINGS.
MODEL
CUTOUT DIMENSIONS
NOTCH
SETBACKS
POWER
u
GAS
LINE
W
DH N
S1(MIN.)
S2
AMPS
AAEP-26
24-1/2" 19-3/4"
9-1/2"
7/8"
5-3/4"
~
w
ARTP-32 / AAEP-32
30-1/2" 19-3/4"
9-1/2"
7/8"
5-3/4"
~
0.71
v
w
ARTP-36
34-1/2" 19-3/4"
9-1/2"
7/8"
5-3/4"
~
0.71
v
w
ARTIJ-26
27-1/4" 23-5/8" 10-1/4"
7/8"
1-5/8"
~
x
ARTIJ-32
33-1/4" 23-5/8" 10-1/4"
7/8"
1-5/8"
~
xx
ARTIJ-36
37-1/4" 23-5/8" 10-1/4"
7/8"
1-5/8"
~
xx
ART-SB1
11" 15"
~~
1-1/2"
~
y
ARTP-SDL /SDR
13-7/8"
~
18-1/2"
~
~~
ARTP-DD
27-1/4"
~
18-1/2"
~
~~
ARTP-DDC
29-3/8" 18-5/8" 18-1/2"
~
~~
ARTP-2DR
14-5/8" 18-5/8" 12-1/2"
~
~~
ARTP-TC
12-1/2" 18-1/2" 26-1/2"
~
~~
ARTP-PWC
6-1/4" 8-1/4"
~~
~
4-5/8"
H
N
W
D
D
S2
W
W
H
S1
S1
D
SIDE BURNER &
TRASH CHUTE
UNDERCOUNTER
OUTLET REQUIRED
FOR GRILL LIGHTS
ON ARTP GRILLS
COUNTERTOP OUTLET REQUIRED
F
OR POWER TO ROTISSERIE UNITS
ART-ROT26,30 OR 36
POWER: 115 VAC - 0.38AMPS
GRILLS &
INSULATED
JACKETS
MEASURED TO
CABINET FACE
DOORS,
DRAWERS
&
TRASH
CENTER
Specification and Cutouts
-Gas Requirements
Nat. - 1/2" NPT connection
5" WC pressure
L.P. - 3/8" ODF connection
10" W.C. pressure
Note: Standard configuration
is for natural gas. For L.P. models,
add “LPto part # when ordering.