TILE TRAY INSTALLATION:
GAS CONNECTION - LIQUID PROPANE (LP):
NOTE: THIS APPLIES TO LP MODELS ONLY. LP MODELS HAVE THE LETTERS “LP” IN THE
MODEL NUMBER.
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury.
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-B149.2, Propane Installation Code.
Manifold pressure with LP Operating: 10.0” W.C. Non-operating: 11.2” W.C.
L.P. TANK REQUIREMENTS:
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H x Ø12-1/4”). The tank must be
installed in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should
be checked by your LP supplier. Never use a cylinder with a damaged valve.
Remove top grill.
Tile tray located over
the gas burners