Operating instructions

SHUTTLE TO NEEDLE RELATIONSHIP:
Correctly Timing the Needle with the motor switched off.
Set the Stitch Length Lever to the “0” Position. Then turn the Handwheel in a
counter-clockwise rotation and raise the needle bar from “Bottom-Dead-Center”,
the lowest position, up 4 mm or 5/32. The Shuttle Hook Point should now be
directly behind and in the center of the Needle just above eye of the needle.
At 4 mm up, the measurement from the bottom of the needle clamp to the top of
the standard needle plate
#
43337 should be at 31 mm or 1-7/32”.
Page 10
Shuttle Hook Point
to the Needle Relationship
as viewed from behind
the needle on the rear left
side, and from left to right.
Shuttle Hook Point
to the Needle Relationship
as viewed from behind the
needle and from the
right to left side.
Shuttle Hook
Point
B.
Shuttle Hook
Driver
E.
Shuttle Hook
Race
C.
Bobbin Case
Opener Latch
G.
Needle
Guard
Needle
Needle
Guard
Shuttle Hook
Point
B.
Shuttle Hook
Point
B.