Mini MAU Installation Guide
Copyright Notice Copyright 1993 by Asanté Technologies, Inc. All rights reserved. No part of this manual, or any associated artwork, software, product design or design concept, may be copied, reproduced or stored, in whole or in part, in any form or by any means mechanical, electronic, optical, photocopying, recording or otherwise, including translation to another language or format, without the express written consent of Asanté Technologies, Inc.
Technologies, Inc. for a Returned Merchandise Authorization (RMA) number, that (2) you clearly write the RMA number on the outside of the package, and that (3) you return it, postage prepaid, during the warranty period. This warranty is exclusive and is limited to Asanté Ethernet network interface products.
minimau Page 1 Monday, August 26, 1996 11:02 AM Introduction Thank you for purchasing a Mini MAU from Asanté Technologies. The Asanté Mini MAU is an ideal network solution for connecting computers and other peripherals with an AUI port to a 10BaseT, 10Base2 or 10BaseFL Ethernet network.
minimau Page 2 Monday, August 26, 1996 11:02 AM Asking for assistance To contact Asanté Technical Support for help: (800) 622-7464 Telephone (408) 435-0706 Fax (408) 432-6018 Applelink mail ASANTE.TECH Internet mail support@asante.
minimau Page 3 Monday, August 26, 1996 11:02 AM Product Overview Asanté Mini MAUs The Asanté Mini MAU plugs directly onto the back of your PC, Macintosh or any other network device that has a AUI interface. Asanté offers three types of MAUs: ❏ AUI to Mini MAU Unshielded Twisted Pair (UTP) AUI to Mini MAU Thin Coax AUI to Mini MAU Fiber ❏ ❏ The Mini MAUs are compatible with any Ethernet device that has an AUI Ethernet port.
minimau Page 4 Monday, August 26, 1996 11:02 AM Summary of Mini MAU Features • Standards based transceivers for unshielded twisted pair (UTP), thin and fiber-optic Ethernet. • Full compatibility with IEEE 802.3 specifications for 10BaseT, 10Base2, and 10BaseFL Ethernet. • Diagnostic LEDS • Ability to turn HBE on or off. • Can be used as an accessory to AsantéHub 2072 Repeater modules.
minimau Page 5 Monday, August 26, 1996 11:02 AM Mini MAU Media and Connectors Mini MAU 10BaseT Mini MAU 10BaseFL Media Connector Port UTP RJ-45 Unshielded Twisted Pair AUI Fiber ST AUI Thin Coax BNC AUI Mini MAU 10Base2 Mini MAU Mini MAU Page 5
minimau Page 6 Monday, August 26, 1996 11:02 AM Switches AUI connection (15-pin) Six LEDs RJ-45 connection Figure 1 Mini MAU for 10BaseT Mini MAU Page 6
minimau Page 7 Monday, August 26, 1996 11:02 AM Installation Mini MAU The installation of an Asanté Mini MAU is very simple: 1 Locate the AUI port on the device. The AUI is on the rear of your hub or computer. Externally it consists of the 15 pin AUI connector. 2 3 Connect the Mini MAU to the AUI port. Connect the Ethernet cable to the Mini MAU. Twisted-pair cable (10BaseT) with Mini MAU Connect the 10BaseT Mini MAU to the device’s AUI port.
minimau Page 8 Monday, August 26, 1996 11:02 AM Switches AUI connection (15-pin) Six LEDs BNC connection Figure 2 Mini MAU for Thin Ethernet Mini MAU Page 8
minimau Page 9 Monday, August 26, 1996 11:02 AM Thin cable (10Base2) with Mini MAU Connect the 10Base2 Mini MAU to the device’s AUI port. Before the 10Base2 Mini MAU is connected to the thin Ethernet cable, there may be a straight-through (barrel) BNC connector in the cable at the location where a node connection is available. Simply remove the barrel connector, and connect a “T” connector to the BNC port on the Mini MAU. The connector slips on, twists, and locks in place.
minimau Page 10 Monday, August 26, 1996 11:02 AM Switches AUI connection (15-pin) Fiber connection Six LEDs Fiber connection Figure 3 Mini MAU for Fiber Mini MAU Page 10
minimau Page 11 Monday, August 26, 1996 11:02 AM Fiber Connect the 10BaseFL Mini MAU to the device’s AUI port. Connect the Mini MAU fiber connector to the fiber cable with ST connectors. ❖ Note: Check with your network administrator before disconnecting cable. Other users must be warned of the interruption of network operations. Even if the network uses self-terminating media or connectors, users downstream from the break will be affected.
minimau Page 12 Monday, August 26, 1996 11:02 AM LEDs and Switches for the Mini MAU Mini 10BaseT MAU LED Display LED Color Status Power on Green MAU ON receiving power from AUI Link Green ON Link OK OFF Link failed Receive Green ON MAU is receiving Transmit Green ON MAU is transmitting Polarity Yellow ON MAU polarity is reversed Collision Yellow ON Collision on Network Mini MAU Page 12
minimau Page 13 Monday, August 26, 1996 11:02 AM Switches for 10BaseT MAU There are three switches on the side on the 10BaseT Mini MAU.The default settings for the switches are identified below. ❏ Heartbeat Enable (HBE)function disabled.
minimau Page 14 Monday, August 26, 1996 11:02 AM ❖ Note: If the MAU is used with a hub or repeater this switch should be disabled.❖ Link Integrity Enabled Test Switch This switch is normally enabled to verify cable link. This switch can be disabled to work with non-10BaseT compliant repeaters and hubs. Polarity Correction This switch, when enabled, inverts the polarity of a signal automatically if a received signal has reverse polarity. Wiring problems cause reverse polarity.
minimau Page 15 Monday, August 26, 1996 11:02 AM Hub AUI connection (15-pin) 10 Base F MAU Fiber connector 10 Base F network Figure 4 Mini MAU Fiber to hub Mini MAU Page 15
minimau Page 16 Monday, August 26, 1996 11:02 AM Mini 10BaseFL MAU LED Color Status Power on Green MAU ON receiving power from AUI Link Green ON Link OK OFF Link failed Receive Green ON MAU is receiving Transmit Green ON MAU is transmitting Jabber Yellow ON Transceiver stops transmitting due to a packet transmission exceeding more than 20 ms.
minimau Page 17 Monday, August 26, 1996 11:02 AM Switches for 10Base-F MAU The default settings are identified below: ❏ Loopback Test Switch enabled. (1, switch UP) ❏ HBE Switch disabled. (1, switch UP) The default settings are Loopback switch enabled and HBE Switch disabled. Loopback Test Switch When this switch is enabled the AUI transmit pair data is looped back to the AUI receiver pair.
minimau Page 18 Monday, August 26, 1996 11:02 AM Macintosh Five LEDs AUI connector Mini MAU 10Base2 Thin Ethernet network Figure 5 Mini MAU Thin Ethernet to Macintosh Mini MAU Page 18
minimau Page 19 Monday, August 26, 1996 11:02 AM Mini 10Base2 MAU LED Color Status Power ON Green MAU ON receiving power from AUI HBE ON Green ON HBE is ON Switch set to “Down” (0) position. Receive Green On MAU is receiving or transmitting Transmit Green ON MAU is transmitting Jabber Yellow ON Transceiver stops transmitting due to a packet transmission exceeding more than 20 ms.
minimau Page 20 Monday, August 26, 1996 11:02 AM Switches for 10Base2 MAU The default settings are identified below: ❏ Termination disabled (1, switch UP) ❏ HBE disabled (1, switch UP) Termination The Mini 10Base2 MAU has a built-in 50ohm termination resistor. This is useful if the user does not have a terminator. If enabled the switch is in the “Down” (0) position and the 50 ohm termination is connected across the BNC.
minimau Page 21 Monday, August 26, 1996 11:02 AM ❖ Note: All Asanté MAUS attached to a hub or repeater should have HBE disabled. For example, if the Mini MAU is attached to an AsantéHub 1012 or 2072.❖ Installing a Mini MAU for the AsantéHub 2072 To install an Asanté Mini MAU into the recessed port on the double-slotted AsantéHub 2072 do the following: 1 2 Unscrew the two ejector screws on each side of the module’s front panel and pull out the module approximately four to five inches from the chassis.
minimau Page 22 Monday, August 26, 1996 11:02 AM 3 4 Insert the Mini MAU by handguiding it into its recessed slot until the MAU is securely fastened to it’s connector. Re-insert the module into the chassis.
minimau Page 23 Monday, August 26, 1996 11:02 AM Specifications Mini MAU Power ❏ 120mA@ 11-16VDC from the Ethernet device AUI. Environmental ❏ 1 to 50 C Dimensions ❏ Mini MAU 3.35”x 1.65” x 0.