Use and Care Guide

-4-
INSTALLATION OPTIONS
Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result in
property damage, bodily injury, or even death, see specic installation details for clearances and other installation
requirements.
Freestanding Unit - supported by pedestal/legs and placed on a non-combustible oor surface in compliance
with clearance requirements for a freestanding stove installation.
Alcove Unit - supported by pedestal/legs and placed on a non-combustible oor surface in compliance with
clearance requirements for an alcove installation.
Your pellet stove may be installed to code in either a conventional or mobile home (US Only), see the “Special
Mobile Home Requirements” section of this manual. It is recommended that only a authorized technician install
your pellet stove, preferably an NFI certied specialist.
CAUTION: Do not connect to or use in conjunction with any air distribution ductwork.
Installation
FLOOR PROTECTION
This unit must be installed on a non-combustible oor surface. If a oor pad is used, it should be certied or equal.
The oor pad or non-combustible surface should be large enough to extend a minimum of 6” (153 mm) in front,
6” (153 mm) on each side, and 1” (26 mm) behind the stove. Floor protection must extend under and 2” (51
mm) to each side of the chimney tee for an interior vertical installation. A Floor Protector of 1” (26 mm) thick is
recommended for this installation. Canadian installations require 18” (450 mm) in front of the unit.
Dimensions in mm
A Rear (through wall) 1 25
B Side 6 152
C Front *6 *152
D Rear (interior vertical) 2 50
* Canada installation requires
18” (450 mm) in front of the unit.
BB
D
C
A
B B
C
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the malfunction
of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer if
you have any questions.
E
BACK WALL
BACK WALL
SIDEWALL
SIDEWALL
F
F
G
G
E
ADJACENT WALL
ADJACENT WALL
H
ADJACENT WALL
H
H
ADJACENT WALL
H
Side Wall Clearances Parallel Installation
Side Wall Clearances Corner Installation
J
Alcove Clearances
CLEARANCES
Your pellet stove has been tested and listed for installation in residential, mobile home, and alcove applications
in accordance with the clearances given in this manual. NOTE: Distance “B” on the side of your pellet stove may
need to be greater than the minimum required clearance for suitable access to the control panel.
in mm
PARALLEL
E Backwall to unit 2 50
F Sidewall to ue 13 330
G Sidewall to top edge of unit 8 203
CORNER H Adjacent wall to unit 8 203
ALCOVE J Alcove depth 36 914