User manual

Chassis Fan 1/2 Profile [Standard]
This item allows you to set the appropriate performance level of the chassis fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust depending
on the chassis temperature.
[Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan operation.
[Turbo] Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set Chassis Fan 1/2 Profile to [Manual].
Chassis Fan 1/2 Upper Temperature [70]
Use the <+> or <‑> keys to adjust the upper limit of the CPU temperature. The values
range from 40°C to 75°C.
Chassis Fan 1/2 Max. Duty Cycle(%) [100]
Use the <+> or <‑> keys to adjust the maximum chassis fan duty cycle. The values
range from 60% to 100%. When the chassis temperature reaches the upper limit, the
chassis fan will operate at the maximum duty cycle.
Chassis Fan 1/2 Middle Temperature [45]
Use the <+> or <‑> keys to set the value for Chassis Fan Middle Temperature.
Chassis Fan 1/2 Middle Duty Cycle(%) [60]
Use the <+> or <‑> keys to adjust the chassis fan middle duty cycle. The values range
from 60% to 100%.
Chassis Fan 1/2 Lower Temperature [40]
Use the <+> or <‑> keys to adjust the chassis fans’ lower temperature. The values
range from 40°C to 75°C.
Chassis Fan 1/2 Min. Duty Cycle(%) [60]
Use the <+> or <‑> keys to adjust the minimum chassis fan duty cycle. The values
range from 60% to 100%. When the CPU temperature is under the lower limit, the
chassis fan operates at the minimum duty cycle.
2-40 Chapter 2: Getting started