Network Router User Manual

9-12 DCP Cabling and Administration
________________________________________________________________________________________________
________________________________________________________________________________________________
________________________________________________________________________________________________
ENHANCED MODE - PROCEDURE: 014, WORD: 1
BEARER CAPABILITY CLASS OF SERVICE - CALL OPTIONS
1. Bearer Capability COS: 6 DEFAULT CAPABILITIES
2. Transport Mode: 0 Circuit 14. Transport Mode: 0 Circuit
3. Information Type: 0 Restrict 15. Information Type: 0 Restricted
16. Bearer Capability: 4 Mode 0
CALL TYPES AND ACTION TAKEN
4. Voice: 0 Circuit switch the call
5. Voice Grade Data: 1 Insert a mode 2-to-analog modem pool facility
6. Mode 0: 0 Circuit switch the call
7. Mode 1: 0 Circuit switch the call
8. Mode 2: 0 Circuit switch the call
9. Mode 3: 0 Circuit switch the call
10. Unknown Digital: 0 Circuit switch the call
11. Unknown Analog: 1 Insert a mode 2-to-analog modem pool facility
12. Mode 3/2: 0 Circuit switch the call
13. X.25: 0 Circuit switch the call
Connected to CC0 ON-LINE MAJOR
MINOR RUN TAPE BUSY OUT IN USE WAIT
enter command: _
3 Data 5 Help 6 Field 7 Input 8 Cmds
Figure 9-6. Manager II Administration of DCP Port (Proc 014, Word 1)
3. The DCP extensions default to BCCOS 1. Change this to BCCOS 6 as shown in these examples.
This allows the DCP port to communicate with either a digital or analog outside facility.
A call to/from this port will be circuit switched unless it is voice-grade data or unknown analog. In
these cases, a modem pool will be inserted.