INSTRUCTION MANUAL PLMB 9KEHPW-410 /12KEHPW-410 /15KEHPW-410 P L M B mono bloc s ENGLISH
GB SAFETY instructions IMPORTANT! • The unit is designed for indoor operation. • Rating: This unit must be connected to a 220-240 V~ / 50 Hz earthed outlet. • The installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the electrical installation, have it checked and if necessary modified by a qualified electrician. • The air conditioner is safe. However, as with other electrical appliances, use it with care.
GB WARNING • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty.
GB PARTS 1 5 2 6 3 3 7 4 8 9 10 1. 2. 3. 4. Air outlet Control panel Carrying handle Caster wheels 5. 6. 7. 8. 9. 10.
GB Active carbon filter 3M™ High Air Flow filter (Optional) Remote control with LCD Spiral Water Pipe with Connector Water container Exhaust hose Slide bar connector Telescopic slide bar CONTROL PANEL Controls ON/OFF UP DOWN MODE TIMER Display COOLING FAN HEAT HOURS:MINUTES TEMPERATURE SLEEP FAN SPEED SWING
GB AutoDrain NanoMist Technology™ Assembly 1 3 5 7 Attach Window Slide Bar Connector to Exhaust Hose by twisting as shown. Connect the female half of the quick connector at the end of the spiral water pipe to the male part in the hot air outlet pipe. Assemble the hot air hose on the unit. Unfold flexible hose with attached hose adapter connector, and snap into Window Slide Bar. 2 4 6 8 Put spiral water pipe into hot air flexible hose.
GB Installation WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another. In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles. – To place the loose filters in the filter holder. • Take the filter holder out of the air conditioner. • Open the filter holder and place the active carbon filter (black) in the filter holder.
GB Operation ON/OFF Press to switch the unit on, or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash. Press or to adjust the hour. Press momentarily, the 2 right digits of the 4 digits will flash. Press or to adjust the minutes of the clock. Press the -button for 3 seconds again to activate the clock.
GB LCD display are flashing. • Press or to adjust the hour. • Press the -button briefly again, the 2 right digits of the 4 digits are flashing. • Press or to adjust the minutes of the clock in intervals of 5 minutes. The timer is set. After 10 seconds the time display returns. Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00.
GB LCD blue back light In order to switch off the blue back light, press the - and -buttons at the same time. The blue back light will blink twice and goes off after three seconds. By pushing any of the buttons the blue back light will come on again. Air flow On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed. • When the ON-button is pressed, the louvres open to maximum and return to an angle of 75° above the upper plane of the louvres housing.
GB Remote control The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function. Instead of the -button for setting the actual time and for programming the timer, there are 3 push buttons on the remote control as follows: • - for setting the actual time.
GB Air Filters This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air, which includes: a. A screen filter, to remove dust particles. b. An active carbon filter, to remove odours. c. 3M™ High Air Flow filter; to remove unhealthy particles from the air such as pollen, bacteria, animaldander and dust. Selected models have the 3M™ High Air Flow fillter as standard.
GB NOTE! • Remove the 3M™ High Air Flow filter and active carbon filter before seasonal storage and install new filters at the beginning of the new season. The old filters can be disposed in the ‘Non-biological garbage container’. • Replacement filter packages are available directly from Atlantic. • To run the unit without active carbon filter and/or 3M™ High Air Flow filter does not do any harm to the air conditioner. In this case odours and unhealthy dust are not removed from the circulated air.
GB cleaning WARNING! First of all switch off the unit and remove the plug from the wall socket. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Clean the screen filter regularly with a vacuum cleaner. See also “AIR FILTERS” section. NOTE! Never use the air conditioner without the screen filter. trouble shooting Never try to repair or dismantle the air condition yourself.
GB Storage • Empty the internal water container. • Clean the screen filter. • Remove the active carbon filter before end of season storage and install new filters at the beginning of the new season. • The old filters can be disposed of in the ‘Non-biological rubbish container’. Replacement filter packages are available from Atlantic. • Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry. • Store the cable as shown.
YOUR GUARANTEE DOMESTIC AIR CONDITIONERS If this product is found to be defective as a result of faulty materials or workmanship within two years from date of purchase, it will be repaired or replaced free of charge. The purchaser is responsible for sending/returning the unit to/from an approved repairer. Products are non-refundable 14 days from date of purchase.