Empty the internal water container.
Clean the screen filter.
Remove the active carbon filter before end of season
storage and install new filters at the beginning of the new
season.
The old filters can be disposed of in the ‘Non-biological
rubbish container’.
Replacement filter packages are available from Atlantic.
Put the unit in Fan Only mode for a few hours to ensure
that the inside becomes completely dry.
Store the cable as shown.
Protect the unit against dust and store in a dry place, not accessible to children.
Model
PLMB
9KEHPW-410
PLMB
12KEHPW-410
PLMB
15KEHPW-410
Cooling capacity BTU/h
9000 12000 15000
KW
2.6 3.5 4.4
Heating capacity BTU/h
9500 12500 15500
KW
2.8 3.7 4.5
Power consumption -Cooling
-Heating
W
850 1100 1500
900 1200 1400
Current -Cooling A
3.7 4.8 6.5
Current -Heating A
3.9 5.2 6.0
Mains V / Hz / PH
220 - 240 V~/ 50 / 1
Compressor model
Rotary
Fan speeds
3 (2+1 turbo)
Thermostat range ºC
18 - 32
Operating temperature range ºC
5 - 35
Refrigerant / R410A g
340 560 660
Dimensiones (w x h x d) mm
500 x 815 x 415
Net weight kg
31.2 35 35.8
PLMB 9KEHPW-410 series can be connected only to a supply with system impedance no more than 0.210 Ohm.
PLMB 12KEHPW-410 series can be connected only to a supply with system impedance no more than 0.130 Ohm.
PLMB 15KEHPW-410 series can be connected only to a supply with system impedance no more than 0.110 Ohm.
If necessary, please consult your supply authority for system impedance information.
Subject to modifications without prior notice. For greater precision, please refer to the rating label placed on the
product.

Waste electrical products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.