QuickSpecs

1.
2.
3.
The M6412 is a 2U dual-redundant FC Loop 12-bay point to point disk enclosure
with mounting hardware, and the necessary copper FC cables for connecting to an
HSV Controller pair.
NOTE:
NOTE:NOTE:
NOTE:
An EVA requires a minimum of 8 drives per Fibre Channel or FATA drive type
or 6 solid state drives per EVA4400/6400/8400.
The EVA6400/8400 Controller Array can be added on-site into existing EVA configurations (or qualified rack systems), Additional
M6412 drive enclosures (AG638B) can be ordered to expand an EVA4400/6400/8400 configuration:
Ordered for on-site capacity additions to existing EVA4400/6400/8400 configurations.
Ordered for field installation of complete EVA4400/6400/8400 configurations HP cabinets and racks described in Step 3 or
into qualified 3rd party rack systems by HP Global Services.
Installed by HP manufacturing into EVA configurations by ordering the enclosure with the factory integration part number.
Up to eighteen drive enclosures are supported with each pair of HSV400 and up to 27 drive enclosures are supported with
each pair of HSV450 controllers. The M6412 is a 2U dual-redundant FC Loop 12-bay switched disk enclosure with mounting
hardware, and includes the necessary copper FC cables for connecting to an HSV400/450 Controller pair.
Order additional hard disk drives using the SKU's listed in Step 5.
Enterprise Virtual
Enterprise VirtualEnterprise Virtual
Enterprise Virtual
Array Racking for
Array Racking forArray Racking for
Array Racking for
Expansion
ExpansionExpansion
Expansion
The EVA customers have the option to mount supported devices in the rack used for
EVA8400 expansion.
HP 10642 G2 Shock Universal Rack
Power requirements vary based on the equipment to be placed in the rack and the
country power supply. Options are:
AF002A
HP PDU Pivot Kit
May be used when expanding an existing EVA6400/8400 to reclaim 2U of space in a
10000 G2 Series Rack.
AG730A
Modular PDU 24A Low Volt, NA/JPN
252663-D71
#0D2
Modular PDU 24A HV, NA/JPN
252663-D72
#0D2
Modular PDU 32A HV, INTL
252663-B31
#0D2
NOTE:
NOTE:NOTE:
NOTE:
#0D2 feature code designates the PDUs are mounted horizontally in the
bottom of the rack on real rail, above any UPS, and occupies 2U EIA space.
Low voltage PDU 252663-D71 requires additional power distribution module
AF500A. (1) AF500A supports 2 PDUs. Each PDU requires a quantity of 2 AF500As.
AF500A
QuickSpecs
HP 6400/8400 Enterprise Virtual Arrays
HP 6400/8400 Enterprise Virtual ArraysHP 6400/8400 Enterprise Virtual Arrays
HP 6400/8400 Enterprise Virtual Arrays
Configuration Information and Configuration Rules
DA - 13206 Worldwide — Version 17 — August 30, 2011
Page 36