User`s manual

Mediant 1000
H.323 User's Manual 232 Document #: LTRT-83401
Table 6-7: H.323 Configuration Parameters (continues on pages 226 to 232)
ini File Field Name
Web Parameter Name
*
Valid Range and Description
TelProfile_ID
[Tel Profile Settings]
TelProfile_<Profile ID> =
<Profile Name>,<Preference>,<Coder Group ID>,<IsFaxUsed
*>,<DJBufMinDelay *>, <DJBufOptFactor *>,<IPDiffServ
*>,<ControlIPDiffServ*>,<DTMFVolume>,<InputGain>, <VoiceVolume>,<N/A
use $$ instead>,<N/A use $$ instead>, <EnableDigitDelivery>, <ECE>, <N/A
use $$ instead>, <N/A use $$ instead>, <FlashHookPeriod>, <N/A use $$
instead>, <ProgressIndicator2IP>
Preference = (1-10) The preference option is used to determine the priority of
the Profile. Where ‘20’ is the highest preference value. If both IP and Tel
profiles apply to the same call, the coders and other common parameters
(noted by an asterisk) of the preferred Profile are applied to that call. If the
Preference of the Tel and IP Profiles is identical, the Tel Profile parameters
are applied.
For examples:
TelProfile_1 = FaxProfile,1,1,1,40,13,22,33,$$,$$,$$,0,0,0,1,0,0,$$,0,$$
TelProfile_2 =
ModemProfile,2,2,0,40,13,$$,$$,$$,$$,$$,$$,$$,$$,0,0,0,$$,0,$$
$$ = Not configured, the default value of the parameter is used.
(*) = Common parameter used in both IP and Tel profiles.
Note 1: The Tel ProfileID can be used in the Trunk Group table
(TrunkGroup_x parameter).
Note 2: ‘Profile Name’ assigned to a ProfileID, enabling users to identify it
intuitively and easily.
Note 3: This parameter can appear up to 4 times (ID = 1 to 4).
For configuring the Tel Profile using the Web interface, refer to Section
5.5.5.2 on page 108.
CoderName_ID
Defines groups of coders that can be associated with IP or Tel profiles (up to
five coders in each group).
Enter coder groups in the following format:
CoderName_<coder group ID from 1 to 4>=<Coder
Name>,<Ptime>,<Rate>,<Payload Type>,<Silence Suppression Mode>.
Note 1: This parameter (CoderName_ID) can appear up to 20 times (five
coders in four coder groups).
Note 2: The coder name is case-sensitive.
Note 3: If silence suppression is not defined (for a specific coder), the value
defined by the parameter EnableSilenceCompression is used.
Note 4: The value of several fields is hard-coded according to well-known
standards (e.g., the payload type of G.711 U-law is always 0). Other values
can be set dynamically. If no value is specified for a dynamic field, a default
value is assigned. If a value is specified for a hard-coded field, the value is
ignored.
For example:
CoderName_1 = g711Alaw64k,20,,,0
CoderName_1 = g711Ulaw64k,40
CoderName_1 = g7231,90,1,,1
CoderName_2 = g726,$$,2,,0
For configuring the groups of coders using the Web interface, refer to