Table 6-11: E1/T1/J1 Configuration Parameters (continues on pages 246 to 248)
ini File Field Name
Web Parameter Name
Valid Range and Description
DChConfig_x
For a description of this parameter, refer to Table 5-32 on page 152.
ISDNNFASInterfaceID_x
For a description of this parameter, refer to Table 5-32 on page 152.
CASTableIndex_x
For a description of this parameter, refer to Table 5-32 on page 152.
CASFileName_0
CASFileName_1
CASFileName_7
CAS file name (e.g., ‘E_M_WinkTable.dat’) that defines the CAS protocol. It is
possible to define up to eight different CAS files by repeating this parameter.
Each CAS file can be associated with one or more of the gateway trunks using
the parameter CASTableIndex_x.
CASTablesNum
1 to 8. Indicates how many CAS protocol configurations files are loaded.
IdleABCDPattern
For a description of this parameter, refer to Table 5-33 on page 157.
IdlePCMPattern
For a description of this parameter, refer to Table
5-33 on page 157.
LineBuildOut.Loss
For a description of this parameter, refer to Table
5-32 on page 152.
ISDNRxOverlap_x
For a description of this parameter, refer to Table
5-32 on page 152.
ISDNRxOverlap
0 = Disabled (default).
1 = Enabled.
Any number bigger than one = Number of digits to receive.
Note 1: If enabled the gateway receives ISDN called number that is sent in the
‘Overlap’ mode.
Note 2: The Setup to IP is sent only after the number (including ‘Sending
Complete’ Info Element) was fully received (via Setup and/or subsequent INFO
Q.931 messages).
For detailed information on ISDN overlap dialing, refer to Section 10.1 on page
293.
SendMetering2IP
For a description of this parameter, refer to Table 5-18 on page 119.
DigitMapping
For a description of this parameter, refer to Table 5-6 on page 75.
TimeBetweenDigits
For a description of this parameter, refer to Table 5-6 on page 75.
MaxDigits
For a description of this parameter, refer to Table 5-6 on page 75.
TimeForDialTone
For a description of this parameter, refer to Table 5-6 on page 75.
HotLineToneDuration
For a description of this parameter, refer to Table
5-6 on page 75.
HookFlashOption
For a description of this parameter, refer to Table
5-6 on page 75.
IsSpecialDigits
For a description of this parameter, refer to Table 5-6 on page 75.
R2Category
For a description of this parameter, refer to Table
5-21 on page 126.
RegretTime
For a description of this parameter, refer to Table
5-7 on page 80.
HeldTimeout
Determines the time period the gateway can stay on-hold. If a Resume (un-hold
Facility) message is received before the timer expires, the call is renewed. If
this timer expires, the call is released.
-1 = Indefinitely (default).
0 - 2400 =Time to wait in seconds.
Currently applicable only to MFC R2 CAS variants.
ISDN Flexible Behavior Parameters
ISDN protocol is implemented in different Switches / PBXs by different vendors. Several implementations vary a
little from the specification. Therefore, to provide a flexible interface that supports these ISDN variants, the
ISDN behavior parameters are used.
ISDNInCallsBehavior
For a description of this parameter, refer to Table 5-32 on page 152.
ISDNIBehavior
For a description of this parameter, refer to Table
5-32 on page 152.
ISDNGeneralCCBehavior
For a description of this parameter, refer to Table 5-32 on page 152.
ISDNOutCallsBehavior
For a description of this parameter, refer to Table 5-32 on page 152.