9. In the Call Progress Tones file, add a new Reorder Tone with the attributes you found
in the previous step. Ensure that you update the numbers of the successive tones and
the total number of tones in the beginning of the file.
10. Create a Call Progress Tones.dat file using the DConvert Utility (refer to Section E.1
on page 395).
11. Load the new file to the gateway, and then reset the gateway.
E.3 PSTN Trace Utility
These utilities are designed to convert PSTN trace binary files to textual form. The binary
PSTN trace files are generated when the user sets the PSTN interface to trace mode.
E.3.1 Operation
Generating textual trace/audit file for CAS protocols:
To generate a readable text file out of the binary trace file when using CAS protocols,
rename the PSTN trace binary file to CASTrace0.dat and copy it to the same directory
in which the translation utility CAS_Trace.exe is located. Then, run CAS_Trace.exe
(no arguments are required). As a result, the textual file CASTrace0.txt is created.
Generating textual trace/audit file for ISDN PRI protocols:
To generate a readable text file out of the binary trace file when using ISDN protocols,
copy the PSTN trace binary file to the same directory in which the translation utility
Convert_Trace.bat is located. The following files should reside in the same directory:
Dumpview.exe, Dumpview.cfg and ReadMe.txt. Please read carefully the
ReadMe.txt in order to understand the usage of the translation utility. Next, run the
Convert_Trace.bat. As a result, the textual file is created.
To start and collect the PSTN trace via the Web, please use the following instructions.
(Refer to Figure E-14 for a view of the Trunk Traces). Also, please note if the PSTN trace
was of a PRI of CAS collection based on the framer involved in the trace. This information
is needed to properly parse the captured data.
¾ To start and collect the PSTN trace via the Web, take these 10
steps:
1. Run the UDP2File utility.
2. Determine the trace file name.
3. Determine the UDP port.
4. Mark the PSTN Trace check box.
5. Click the Run button=> the UDP2File utility starts to collect the trace messages.
6. Activate the Web page by entering <Mediant 1000 IP address>/TrunkTraces, such as:
http://10.8.8.101/TrunkTraces. The user and password is the same for the unit.
7. In the Web page set the trace level of each trunk.
8. Enable the trace via the Web.