F.1.2 Component: AlarmManager#0
The source varbind text for all the alarms under this component is Board#<n>/AlarmManager#0 where
n is the slot number.
Table F-11: acActiveAlarmTableOverflow Alarm Trap
Alarm:
acActiveAlarmTableOverflow
OID:
1.3.6.1.4.15003.9.10.1.21.2.0.12
Default Severity:
Major
Event Type:
processingErrorAlarm
Probable Cause:
resourceAtOrNearingCapacity (43)
Alarm Text:
Active alarm table overflow
Status Changes:
Condition:
Too many alarms to fit in the active alarm table
Alarm status:
Major
Condition:
After raise
Alarm status:
Status stays major until reboot. A clear trap is not sent.
Note:
The status stays major until reboot as it denotes a possible loss of information
until the next reboot. If an alarm is raised when the table is full, it is possible that
the alarm is active, but does not appear in the active alarm table.
Corrective Action:
Some alarm information may have been lost, but the ability of the device to
perform its basic operations has not been impacted. A reboot is the only way to
completely clear a problem with the active alarm table. Contact your first-level
group.
F.1.3 Component: Chassis#0
The source varbind text for the alarm under the component below is Chassis#0/FanTray#0.
Table F-12: acFanTrayAlarm Alarm Trap
Alarm:
acFanTrayAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.29
Default Severity:
Critical
Event Type:
equipmentAlarm
Probable Cause:
heatingVentCoolingSystemProblem
Alarm Text:
Fan-Tray Alarm.
Status Changes:
Condition:
Fan-Tray is missing
Alarm status:
Critical
<text value>: Fan-Tray Alarm. Fan-Tray is missing.
Condition:
One or more fans in the Fan-Tray are faulty.
Alarm status:
Major
<text value>: Fan tray is in place and fans are working.
Condition:
Fan is faulty.
Alarm status:
Cleared