User`s manual

H.323 User's Manual F. SNMP Traps
Version 5.0 417 December 2006
The source varbind text for the alarm under this component is
Chassis#0/PowerSupply#<m>, where m is the power supply’s slot number.
Table F-13: acPowerSupplyAlarm Alarm Trap
Alarm:
acPowerSupplyAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.30
Default Severity:
Critical
Event Type:
equipmentAlarm
Probable Cause:
powerProblem
Alarm Text:
Power-Supply Alarm. Power-Supply is missing.
Status Changes:
Condition:
The HA (High Availability) feature is active and one of the power supply units is
faulty or missing.
Alarm status:
Major
Condition:
PS unit is placed and working.
Alarm status:
Cleared
F.1.4 Component: EthernetLink#0
The source varbind text for all the alarms under this component is Board#<n>/EthernetLink#0 where n
is the slot number. This trap relates to the Ethernet Link Module (the #0 numbering doesn’t apply to
the physical Ethernet link).
Table F-14: acBoardEthernetLinkAlarm Alarm Trap
Alarm:
acBoardEthernetLinkAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.10
Default Severity:
Critical
Event Type:
equipmentAlarm
Probable Cause:
underlyingResourceUnavailable (56)
Alarm Text:
Ethernet link alarm: <text>
Status Changes:
Condition:
Fault on single interface
Alarm status:
major
<text> value:
Redundant link is down
Condition:
Fault on both interfaces
Alarm status:
critical
<text> value:
No Ethernet link
Condition:
Both interfaces are operational
Alarm status:
cleared
Corrective Action:
Ensure that both Ethernet cables are plugged into the back of the system. Inspect
the system’s Ethernet link lights to determine which interface is failing. Reconnect
the cable or fix the network problem